Figure 1-  7 VTH150xA-A8 

 

Figure 1-  8 VTH150xCS -A8 

Some 7 ” analog VDP only have power and info indicators, and their shapes vary among 

different models. Please see Chart 1- 2. 

No. 

Name 

Description 

Power 

Power works as  usual, light on; 

Info 

When there is no announcement or alarm info, light turns on if arm; light 

turns off if disarm ; 

When there is announcement but no alarm info, light flashes slowly. 

When there is alarm info, light flashes intensely. 

Network 

When communication with door station is normal, light turns on; if there is 

abnormality,  light  turns  off.  Only  VTH1500A  and  VTH1500A-A8  ha ve 

network indicator. 

DND(Do not 

disturb) 

When DND is on, light remains on; when DND is off, light remains off. Only 

VTH1500A and VTH1500A-A8 have DND indicator. 

Chart 1- 2 

Chapter 2 Basic Function Introduction 

2.1 Bidirectional Talk with Management Center 

 

Under  any  interface,  by  pressing  SOS  button,  you  may  immediately  switch  to  call 

management center, and if the call goes through, you will hear corresponding audio response 

of  long  and  slow  beeps  from  VDP;  if  the  call  does  not  go  through;  you  will  also  hear 

corresponding audio response as short and fast beeps from VDP. You may press SOS button 

again to end the call, and VDP will return to standby interface.   

 

When supervisor station calls VDP, VDP  will ring, and you may answer by pressing call 

button.  You  may  end  call  by  pressing  call  button  again,  and  VDP  will  return  to  standby 

interface. 

2.2 Visual Bidirectional Talk with Door Station 

 

When door station calls VDP, VDP will ring, meanwhile door station video will be displayed 

on screen. You may press call button to answer and then you may perform a bidirectional talk 

with the door station, while the screen continues displaying video from door station.  You may 

Summary of Contents for VTH150x-A8

Page 1: ...7 Analog VDP User s Manual V 1 0 0 ...

Page 2: ...nt Center 6 2 2 Visual Bidirectional Talk with Door Station 6 2 3 Monitoring Function 7 2 4 Unlocking Function 7 2 5 DND Function 7 2 6 Viewing Announcement 7 2 7 Alarm Function 7 2 7 1 Arming Disarming Function 7 2 7 2 Alarm Message and Reporting Function 7 Chapter 3 Technical Specifications 8 Chapter 4 Device Interface Instruction 9 Chapter 5 Device Installation Guide 10 Chapter 6 FAQ 10 ...

Page 3: ...ble for any problems caused by unauthorized modifications or attempted repair The device should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Chapter 1 General Introduction 1 1 Product Appearance The product is classified into the following models Please see Figure 1 1 Figure 1 2 Figure 1 3 Figure 1 4 and Figure 1 5 Figure 1 1 VTH150xA VTH150x ...

Page 4: ...Figure 1 3 VTH150xB VTH150xB A8 Figure 1 4 VTH150xAS VTH150xAS A8 ...

Page 5: ...sarm 3 Call Press the button when being called you can answer call press the button during a call you can hang it up Under standby status long press call button for 5s you can turn on or turn off DND if it is already on 4 Monitor Monitor door station video Under standby status you may press this button to view announcement if available and you may press this button to view alarm info if available ...

Page 6: ...unction Introduction 2 1 Bidirectional Talk with Management Center Under any interface by pressing SOS button you may immediately switch to call management center and if the call goes through you will hear corresponding audio response of long and slow beeps from VDP if the call does not go through you will also hear corresponding audio response as short and fast beeps from VDP You may press SOS bu...

Page 7: ...o alarm VDP receives message sent from platform and the indicator flashes slowly By pressing monitor button you can view announcement which is added in the video on door station in rolling display You can exit announcement viewing by pressing monitor button again Note When there is alarm you must confirm the alarm before viewing announcement 2 7 Alarm Function 2 7 1 Arming Disarming Function Under...

Page 8: ...ported to management center after local display Chapter 3 Technical Specifications Technical specifications are as follows please see Chart 3 1 Video Video CVBS composite video Audio Bidirectional Talk 1 ch audio input from analog signal of microphone 1 ch audio output which drives loudspeaker via amplifier Display Screen Dimension Color 7 TFT LCD Resolution 800 480 Alarm Input Wired 8 ch alarm in...

Page 9: ... Make VTH1500CS A8 an axample Among 7 analog VDP in different models locations of interface are slightly different but their functions are identical Please see Chart 4 1 No Name Description 1 Alarm Interface 8 ch alarm 2 ch GND Some models do not have alarm function and only models ending in A8 have that function ...

Page 10: ... plug in the device to power supply after troubleshoot 3 Device installation and test must be done by professional staff If there is any malfunction or failure please do not try to dismount or fix it by yourself and please contact after sales department for assistance Please refer to Figure 5 1 as guide Chapter 6 FAQ Q The screen on VDP is black and the indicator remains off what should I do A Che...

Page 11: ...Slight difference may be found in user interface All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...

Reviews: