Figure 2-97 Alarm port
Table 2-45 Alarm port description
Icon
Function
1–16
ALARM1–ALARM16. The alarm becomes activated in the low level.
NO1 C1, NO2 C2, NO3 C3,
NO4 C4
Four NO activation output groups. (On-off button).
NO5 C5 NC5
One NO/NC activation output group. (On-off button).
CTRL (CTRL 12 V)
Control power output. Disable power output when alarm is canceled.
Current is 500 mA.
P (+12 V)
Rated current output. Current is 500 mA.
GND.
A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120 TΩ between A/B cables if there are
too many PTZ decoders.
●
Different models support different alarm input ports. Please see the specifications sheet for
detailed information.
●
Slight difference might be found on the alarm port layout.
2.3.2 Alarm Input Port
Connect the positive end (+) of the alarm input device to the alarm input port (ALARM IN 1–16) of
the NVR. Connect the negative end (-) of the alarm input device to the ground end (
) of the NVR.
User's Manual
70
Summary of Contents for NVR2104-I2
Page 1: ...ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 3 3 Network Video Recorder User s Manual...
Page 84: ...Figure 2 98 Alarm input port 1 User s Manual 71...
Page 132: ...Figure 5 8 Unlock pattern login User s Manual 119...
Page 147: ...Figure 5 23 AcuPick human detection User s Manual 134...
Page 151: ...Figure 5 27 Shortcut menu 1 User s Manual 138...
Page 217: ...Figure 5 93 Custom search 2 Step 8 Configure the search conditions as needed User s Manual 204...
Page 326: ...Figure 5 197 TCP IP Step 2 Click to configure the NIC card and then click OK User s Manual 313...
Page 376: ...Figure 5 247 Pattern login User s Manual 363...
Page 412: ...Figure 5 285 File management Step 2 Click Add User s Manual 399...