After you complete smart track setup, please go to the preview interface and then right click mouse, and
then select Smart track, you can view the corresponding video. Please refer to chapter 4.15.7 for detailed
information.
4.15.8 Alarm Settings
Before operation, please make sure you have properly connected alarm devices such as buzz er.
In the main menu, from Setting->Event->Alarm, you can see alarm setup interface.
4.15.8.1 Local alarm
Local alarm refers to the alarm signal system detects from the alarm input port.
In the main menu, from Setting->Event->Alarm->Local, the interface is shown as in
Alarm in: Here is for you to select channel number.
Type: normal open or normal close.
PTZ activation: Here you can set PTZ movement when alarm occurs. Such as go to preset, tour&
pattern when there is an alarm. Click “select” button, you can see an interface is shown as in Figure
4-163.
Period: Click set button, you can see an interface is shown as in Figure 4-164. There are two ways
for you to set periods. There are max 6 periods in one day. There are four record types: regular,
motion detection (MD), Alarm, MD & alarm.
In
Figure 4-164, Select icon
of several dates, all checked items can be edited together.
Now the icon is shown as
.
Click
to delete a record type from one period.
In
Figure 4-164. Click button
after one date or a holiday, you can see an interface shown
as in Figure 4-165. There are four record types: regular, motion detection (MD), Alarm, MD &
alarm.
Anti-dither: Here you can set anti-dither time. Here you can set anti-dither time. The value ranges
from 5 to 600s. The anti-dither time refers to the alarm signal lasts time. It can be seem as the alarm
signal activation stays such as the buzzer, tour, PTZ activation, snapshot, channel record. The stay
time here does not include the latch time. During the alarm process, the alarm signal can begin an
anti-dither time if system detects the local alarm again. The screen prompt, alarm upload, email and
etc will not be activated. For example, if you set the anti-dither time as 10 second, you can see the
each activation may last 10s if the local alarm is activated. During the process, if system detects
another local alarm signal at the fifth second, the buzzer, tour, PTZ
activation, snapshot, record
channel will begin another 10s while the screen prompt, alarm upload, email will not be activated
again. After 10s, if system detects another alarm signal, it can genera te an alarm since the
anti-dither time is out.
Show message: System can pop up a message to alarm you in the local host screen if you enabled
this function.
Alarm upload: System can upload the alarm signal to the network (including alarm centre) if you
enabled current function.
Send email: System can send out email to alert you when alarm occurs.
Summary of Contents for HCVR82**A-S3 Series
Page 1: ...Dahua HDCVI Standalone DVR User s Manual Dahua HDCVI Standalone DVR User s Manual V1 1 0 ...
Page 84: ...72 Figure 4 44 Figure 4 45 ...
Page 102: ...90 Figure 4 73 Figure 4 74 ...
Page 104: ...92 Figure 4 76 Figure 4 77 ...
Page 120: ...108 Figure 4 93 Check a file name double click file or click to play ...
Page 158: ...146 Figure 4 135 Figure 4 136 ...
Page 167: ...155 Figure 4 145 Click Draw button to draw the tripwire See Figure 4 146 Figure 4 146 ...
Page 183: ...171 Figure 4 162 Figure 4 163 ...
Page 190: ...178 Figure 4 171 Figure 4 172 ...
Page 191: ...179 Figure 4 173 Figure 4 174 ...
Page 199: ...187 4 186 and Figure 4 187 Figure 4 186 Figure 4 187 ...
Page 275: ...263 Figure 5 60 Figure 5 61 ...
Page 289: ...277 Figure 5 77 Click to draw the rule See Figure 5 78 Figure 5 78 ...
Page 349: ...337 ...
Page 358: ...346 the sound ventilation Please check and maintain the device regularly ...
Page 360: ...348 896K 393M 1024K 450M 1280K 562M 1536K 675M 1792K 787M 2048K 900M ...
Page 376: ...364 ...