270
Note
If there is no HDD, system max supports 1024 logs.
If you have connected to the unformatted HDD, system max supports 5000 logs.
If you have connected to the formatted HDD, system max supports 500,000 logs.
System operation logs are saved in system memory. Other types of logs are saved in
the HDD. If there is no HDD, other types of logs are saved in the system memory too.
The logs are safe when you format the HDD. But the logs may become loss once you
removed the HDD.
4.11
Setting
4.11.1 Camera
4.11.1.1 Remote Device (
For digital channel only
)
4.11.1.1.1 Remote Device
In the main menu, from Camera ->Remote, you can go to an interface shown as in Figure
4-64. Here you can add/delete remote device and view its corresponding information.
IP search: Click it to search IP address. It includes device IP address, port, device
name, manufacturer, type. Use your mouse to click the item name, you can refresh
display order. Click IP address, system displays IP address from small to large. Click
IP address again, you can see icon, system displays IP address from large to small.
You can click other items to view information conveniently. For the network device
already added to the device, you can see there is a small icon
“*” after the SN in case
there is repeatedly add operation.
Add: Click it to connect to the selected device and add it to the Added device list.
Support Batch add.
You can see the corresponding dialogue box if all digital-channel has connected to
the front-end.
System can not add new device if the device you want to add has the same IP and
TCP port as the device in the list.
Show filter: You can use it to display the specified devices from the added device.
Edit: Click button
or double click a device in the list, you can change channel
setup.
Delete: Please select one device in the Added device list and then click
to
remove.
Status:
means connection is OK and
means connection failed.
Delete
;
Select a device on the Added device list, click Delete button, system
disconnect device first and then remove its name from the list.
Manual add: Click it to add the IPC manually. The port number is 37777. The default
user name is admin and password is admin.
Summary of Contents for HCVR2108C-S2 Series
Page 1: ...Dahua HDCVI Standalone DVR User s Manual Dahua HDCVI Standalone DVR User s Manual V1 8 2 ...
Page 11: ...x APPENDIX F COMPATIBLE WIRELESS MOUSE LIST 479 APPENDIX G EARTHING 480 ...
Page 291: ...278 Figure 4 72 Figure 4 73 ...
Page 322: ...309 Figure 4 105 Figure 4 106 ...
Page 323: ...310 Figure 4 107 Figure 4 108 ...
Page 339: ...326 Figure 4 125 Figure 4 126 ...
Page 340: ...327 Figure 4 127 Figure 4 128 ...
Page 341: ...328 Figure 4 129 Figure 4 130 ...
Page 344: ...331 Figure 4 134 Figure 4 135 ...
Page 351: ...338 Figure 4 145 Figure 4 146 4 11 4 1 2 2Trigger Snapshot ...
Page 353: ...340 Figure 4 148 Figure 4 149 4 11 4 1 2 3Priority ...
Page 384: ...371 Figure 4 188 ...
Page 419: ...406 Figure 5 55 Figure 5 56 ...
Page 432: ...419 Figure 5 71 Figure 5 72 ...