Local Setting 10
The
Local
interface is displayed. See Figure 4-3.
Local
Configure parameters, and for the detailed description, see Table 4-3.
Table 4-3
Local access control parameter description
Parameter
Description
Unlock Responding
Interval
The time interval to unlock again after the previous unlock, and the
unit is second.
Unlock Period
The time amount for which the lock stays open after unlock, and
the unit is second.
Door Sensor Check
Time
If you have installed door sensor, then you can configure the time
period, and If the unlock time exceeds the
Door Sensor Check
Time
, the door sensor alarm is triggered, and the alarm will be sent
to the management center.
Select the
Enable
check box, and the door will not be locked
until the door sensor contacts each other.
If you do not select the
Enable
check box, the door will be
locked after the
Unlock Period
finishes.
First Unlock
Command
You can connect a third-party phone such as SIP phone to your
VTO, and use the command to open the door remotely.
Door Contact Type
Select
NC
or
NO
according to the lock you use.
Click
Save
.
System
This section introduces how to configure the date format, time format, and the NTP server.
On the main interface (Figure 3-1), select
Local Setting > System
.
The
System
interface is displayed. See Figure 4-4.