Submenu
Setting
PWD ERR MAX
Password error maximum.
Set the maximum allowed number of errors in code entry from
the keypad (1 to 4). 00 represents there is no limit. If the
maximum entry time is reached, the current keypad will be
locked for 3 minutes.
If the user password is not completely entered, the system will
automatically return to the home screen after 60 seconds and
record an error.
FACTORY RST
Set whether the controller is enabled to restore factory settings.
●
PART
: Delete all controller data except the wireless devices
codes (such as sensors and sirens).
●
TOTL
: Delete all controller d data.
●
NO
: The reset of factory default procedure will have no
effect.
EOL R VALUE
Set the EOL value to 2.7 K, 4.7 K, or 6.8 K. The panel zones
termination supports NC, NO, 1EOL, 2EOL and 3EOL. For 1 EOL
and 2 EOL, the resistors value can be set to 2.7 K, 4.7 K, or 6.8 K;
for 3 EOL, the resistors value is fixed to 2.7 K (R1, R2), and 6.8 K
(R3).
FIRMWARE VER
Show the firmware version of the controller.
Step 4
Press
to return to the
SYSTEM FUNCTIONS
menu.
Then you can continue with programming other outputs, or press
to return to the
SYSTEM FUNCTIONS
menu from where you can press
and
to move to the next
menu or press
to exit from the installer menu.
7.12 System Timing
Step 1
After entering the installer menu, press
and
to scroll up and down until you reach
the
SYSTEM TIMING
menu.
Figure 7-12 System timing
Step 2
Press
to enter the programming mode.
Step 3
Configure the parameters.
Press
and
to alter the options. Press
to confirm the setting and move to the
next submenu.
The two numeric fields 000.00 represent minutes and seconds.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...