background image

Preface    I 

Preface 

Summary 

The  temperature  of  all  materials  is  higher  than  absolute  zero  (-  273.15 

)  and  radiates 

electromagnetic wave continuously. The thermal imaging camera collects the infrared radiation energy 

emitted  by  the  measured  objects,  and  establishes  the  accurate  corresponding  relationship  between  the 

target  energy  and  temperature  through  complex  temperature  measurement  algorithm  and  blackbody 

temperature measurement calibration and other processes, so as to realize the temperature measurement 

function  of  human  body.  It  is  characterized  by  non-contact,  multi-objective,  fast,  and  no  risk  to  the 

temperature  measurer.  It  can  be  easily  deployed  in  densely  populated  public  places,  and  it  can 

effectively and safely screen the abnormal temperature preliminarily. 

Thermal  imaging  human  body  temperature  measurement,  mainly  through  the  measurement  of 

human  forehead  and  face  temperature  (according  to  the  different  environment  of  about  31-36 

), 

preliminary judgment, found that the suspected abnormal temperature, and then use ear temperature gun 

or mercury thermometer to further confirm. As the skin surface of forehead and face is exposed to the 

air,  the  temperature  changes  due  to  the  influence  of  air  flow  and  sweat.  Generally,  under  the  indoor 

ambient  temperature  of  15 

  in  winter,  if  the  forehead  temperature  exceeds  35 

,  there  is  a 

possibility  of  fever.  For  other  environmental  temperature  conditions,  it  is  recommended  to  measure 

several  samples  on  site,  and  increase  1 

  as  the  alarm  threshold  on  the  basis  of  normal  forehead 

temperature. 

The  human  body  temperature  measurement  requires  high  precision,  which  requires  high 

installation mode, environment and debugging. Please read this article carefully. 

Combined with the support experience of the thermal imaging R & D technical support team, 

this  manual  describes  the  installation  requirements,  common  operations  and  precautions  during  the 

actual  use  of  thermal  imaging  products,  so  as  to  facilitate  the  quick  start  and  reduce  unnecessary 

problems.  For  more  detailed  instructions,  please  refer  to  the  product  manual  and  quick  operation 

manual. 

The content described in this article needs to be analyzed in combination with the actual field equipment, 

which is not the only way. If you have any questions or good suggestions, please contact Xu Fangrong 

(Short NO: 693802), Fang Lu  (Short NO:  685718),  Li  Fuxiang (Short  NO: 638137), Fang Shengdong 

(short: 669126). 

 

 

This manual is only for internal use of Dahua employees. Please do not directly provide it to 

customers or publish it to public platforms such as the Internet. 

 

Reading  objects  include  (but  not  limited  to):  Solution  Engineer,  Pre-sale  /  in-sale  /  after-sale 

technical  support  engineer,  installation  and  debugging  personnel,  product  engineer,  test  engineer, 

marketing and sales personnel and other internal personnel of the company 

 

 

 

Summary of Contents for BF Series

Page 1: ...Installation and commissioning guide for temperature measurement for human body of Dahua thermal camera BF Series Zhejiang Dahua Technology Co Ltd...

Page 2: ...ture exceeds 35 there is a possibility of fever For other environmental temperature conditions it is recommended to measure several samples on site and increase 1 as the alarm threshold on the basis o...

Page 3: ...Preface II Change record Revision date Version number Creater Reviser 2020 01 27 V1 0 2020 01 28 V1 1 2020 01 31 V1 2 2020 02 03 V1 3...

Page 4: ...tallation precautions 2 General settings 7 2 1 Device upgrade 2 2 Image debugging 2 3 Human body temperature detection function debugging 2 3 1 Select the intelligent scheme of human body temperature...

Page 5: ...n of installation guidance video web operation guidance and guidance document should be obtained from the regional delivery supervisor In the future it will be synchronized in the group on the mobile...

Page 6: ...stallation requirements are consistent with bf3221 7mm 1 3 Installation diagram Bf3221 3 5mm installation diagram Blac kbod y Height 2m Side view h u m a n Distance between two objects 2m Height of Bl...

Page 7: ...istance between two objects 3m Height of Blackbody 1 8m Thermal camera focal length 13mm Blac kbod y Sidewalk width 1 5m Top view Thermal camera focal length 13mm 1 4 Real scene diagram BF3221 7mm as...

Page 8: ...ween the camera and blackbody Thermal camera Height 2m Best test distance 3M Height of Blackbody 1 8m Personnel access direction 1 When the artificial diversion channel is lengthened as far as possibl...

Page 9: ...r right side of the thermal imaging picture and the tripod can be protected by temporary fence As follows black body is in the upper right corner of the image It is required that the visible light cha...

Page 10: ...upgraded item No 2 6 01 05 18388 If there is a new iterative process will be notified in the delivery group please pay attention to the group information in time The default to be restored after upgr...

Page 11: ...ent scheme 2 2 2 Blackbody parameter setting Blackbody calibration Note the blackbody parameter setting steps are ignored for the scheme without blackbody a The actual setting of blackbody is 35 b Aft...

Page 12: ...est temperature is within 35 0 2 on average 2 2 3 Drawing of human body temperature detection area a BF3221 7mm BF5401 13mm i The subject stands on the edge of the blackbody 3m away from the camera fa...

Page 13: ...best temperature measurement distance and the measured temperature is generally high or low they can be compensated by temperature correction For example if it is 0 5 lower fill in 0 5 for temperatur...

Page 14: ...11...

Page 15: ...uracy or scrap so as to avoid the scratch of blackbody radiation surface and affect the temperature measurement accuracy Only for indoor use The use environment shall be free from obvious air convecti...

Page 16: ...mperature measurement The actual temperature of the front face and the side face of the same person same position is different With masks the high temperature points are mainly in the forehead ears an...

Page 17: ...ffect is not ideal please provide the Dav video with two channels on site Send Xu Fangrong and Fang Shengdong through Dahua interactive platform select intranet Download for outgoing type After receiv...

Reviews: