background image

 

 

Operation and Daily Maintenance  

 

Do not touch the heat dissipation component of the unit. This part of the unit is hot and may 

cause a burn.  

 

Do not open or dismantle the device; there are no components that a user can fix or replace. 

Opening the unit may cause water leakage or expose components to direct light. Contact the 

manufacturer or a qualified service representative to service the camera or to replace a 

component, including the desiccant. 

 

Dahua recommends the use of a thunder-proof device in concert with the unit. 

 

Do not touch the CCD or the CMOS optic sensor. Use a blower to clean dust or dirt on the lens 

surface. Use a dry cloth dampened with alcohol and gently wipe away any dust on the lens.  

 

Use a dry soft cloth to clean the unit’s housing. If the unit is particularly dusty, use water to dilute 

a mild detergent, apply the diluted detergent to a soft cloth, then gently clean the device. Finally, 

use a dry cloth to wipe the unit dry. Do not use a volatile solvent like alcohol, benzene, or thinner; 

or use a strong detergent with abrasives, which may damage the surface coating or reduce the 

working performance of the unit. 

 

Do not touch or wipe a dome cover during installation, this cover is an optical device. Refer to 

the following methods clean the dome cover:  

  Stained with dirt: Use an oil-free soft brush or blower to gently remove the dirt. 

  Stained with grease or fingerprints: Use a soft cloth to wipe gently the water droplet or the oil 

from the dome cover. Then, use an oil-free cotton cloth or paper soaked with alcohol or 

detergent to clean the lens from the center of the dome to outside. Change the cloth several 

times to ensure the dome cover is clean. 

Lifting Appliance Requirement  

 

Select the proper PTZ dome installation mode and use the proper lifting device to safely lift the 

camera at the installation site. 

 

Ensure that the lifting device has the proper capacity to reach the installation height. 

 

Use the lifting device in accordance with its operating instructions and abide by the device’s 

safety precautions. 

Warnings 

 

Change the default password after the initial login to protect the integrity of the network. 

 

Use the standard accessories provided by the manufacturer and ensure the unit is installed and 

commissioned by qualified professionals.  

 

Protect the lens area from laser radiation when using a laser device to aid in installation and 

leveling of the unit. 

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

Summary of Contents for 6C430IC

Page 1: ...4 MP HDCVI PTZ Camera 6C430IC Quick Start Guide Version 001 001 Dahua Technology USA Inc...

Page 2: ...1 3 Legal Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3...

Page 3: ...protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have pow...

Page 4: ...ng or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of...

Page 5: ...wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the d...

Page 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Page 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Page 8: ...er to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the deta...

Page 9: ...7 3 Installation and Configuration 3 1 Framework and Dimensions The following figures show the dimensions of the device in mm in These images are intended as a reference only Figure 3 1...

Page 10: ...D RS485 Yellow RS485 A Orange RS485 B 3 3 Alarm Setup Certain devices support alarm inputs and outputs check your specific device for alarm capability Alarm Input Refer to Figure 3 3 for alarm input c...

Page 11: ...external pull up level is 5 V and the maximum port current is 5 mA Once the output increases the pull up resistance the alarm decreases the output voltage to the normal state low level at less than 0...

Page 12: ...ing Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country cod...

Page 13: ...Four 4 bolts washers or other fastening hardware to secure the wall mount to the installation medium The hardware must be capable of supporting eight 8 times the weight of the camera and mount Appropr...

Page 14: ...l the composite cable from the dome through the wall mount and pull it out of the other end of the wall mount bracket 8 Align the dome and the mount adapter so that the quick installation screw on the...

Page 15: ...er end of the safety hook to the anchor point on the 64FB Wall Mount Caution Make sure to attach the safety hook and ensure that it is securely fastened to the dome and to the wall mount to improve th...

Page 16: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change...

Reviews: