MAIN GEN
and
LOW VOLTAGE
1 / 3
With GENERATOR selector on ST-BY (after MAIN generator failure), functioning
on ST-BY generator.
1
- GENERATOR selector ........................................................................... MAIN
2
- MAIN GENERATOR RESET pushbutton .............................................. Press
► Fly the airplane ◄
If MAIN GENERATOR successfully connected:
3
- Disconnect non-essential systems.
4
- Voltmeter and ammeter ............................................................. Monitor
► Land as soon as possible ◄
End of procedure ■
If MAIN GENERATOR not successfully connected:
5
- GENERATOR selector ................................................................ ST-BY
6
- ST-BY GENERATOR RESET pushbutton .................................... Press
If ST-BY GENERATOR successfully connected:
7
- Disconnect non-essential systems.
8
- Voltmeter and ammeter .................................................... Monitor
► Land as soon as possible ◄
End of procedure ■
If ST-BY GENERATOR not successfully connected:
Both generators failure is confirmed.
Return to VMC conditions, if possible.
9
- GENERATOR selector .......................................................... OFF
If airplane altitude is > 10,000 ft:
10 - OXYGEN switch ............................................................. ON
Continue ►
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.9.5
PIM - DO NOT USE FOR FLIGHT OPERATIONS