TBM
PILOT’S OPERATING HANDBOOK
700
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Page 3.9.6
Edition 1 -- November 30, 2010
Rev. 0
3.9 -- ELECTRICAL SYSTEM
AMBER CAS MESSAGE
“LOW VOLTAGE” ON
functioning on ”ST--BY GENERATOR”
(after ”MAIN GEN” failure) (3/3)
-- TAS breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- DATA LINK breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- “CD” player
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- “INSTR / CABIN / ACCESS” controls
OFF
. . . . . . . . . . . . . . . . .
-- XPDR 2 breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If icing conditions :
-- “PITOT 1 HTR” switch
Checked ON
. . . . . . . . . . . . . . . . . . . . . .
-- ”WINDSHIELD” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- Maintain minimum recommended speeds (Chapter 4.5 -- “Flight
into known icing conditions”, Paragraph “Ice protection
procedures”, Point 3)
If time permits :
-- ”SVC PLUGS” breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
-- ”AIR COND” breaker
PULL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 -- LAND as soon as possible