9.Software Tools
© China Daheng Group, Inc. Beijing Image Vision Technology Branch 153
b) In the right pane of the tool, select
Auto IP (LLA)
.
c) Select
Save
. When the tool has finished saving, the information in the top pane and the lower left area
will have been updated automatically.
Operation results:
a) Change the camera IP configuration mode to
“LLA”.
b) If operating successfully, the current IP address is allocated with the LLA mode.
9.1.2.6. Change the Device User ID
1) In the top pane of the tool, select the camera whose device user ID you want to change.
2) Enter a new device user ID for the camera in the
Device User ID
field. You can only enter
ASCII
characters. The maximum length allowable is 16 bytes.
3) Select
Save
. When the tool has finished saving, the information in the top pane and the lower left area
will have been updated automatically.
9.1.2.7. Reset Device and Reconnect Device
The button is not available if the device does not support this feature.
Reset Device: When the device is not convenient to power down, but also need to reload the program,
this feature can be used at this time.
Reconnect Device: This function is generally used debugging device using Visual Studio. In debug mode,
the heartbeat timeout is 5 minutes. If the user exits the process without closing device, the device cannot
be reset immediately and device cannot be reopened immediately. In this case, you can use this feature
to release the device control, you can immediately open the device.
Carefully use these two features. The use of those two features during acquisition can cause
acquisition stop immediately.
9.1.3. Precautions
9.1.3.1. Check IP Address Format
It’s not allowed to enter the following IP address in the IP Address field.
1) The IP of Class D: 224.0.0.0 to 239.255.255.254.
2) The IP of Class E: 240.0.0.0~255.255.255.254.
3) The first paragraph of the IP address is 127 and 255.
If you enter one of these IP addresses, a red exclamation mark will be displayed in the right of the IP
Address field and the Save button will be disabled as shown in the Figure 9-4.