Page 17
Specifications for Solar 130LC-V
Mark off a 20 m (65' 7-1/2") test distance, with a 3 m to 5 m (10' to 15') run-up area, and a 3 m to 5 m (10'
to 15', or longer) speed run-off distance.
Travel the excavator back and forth to be sure steering is centered and side frames are perfectly parallel
with the test course.
Operate both travel levers at the fully engaged position and measure the time it takes to cross 20 m (65' 7-
1/2"). Compare measured results against the standard for new machines:
Rotate the turntable 180°. Both tests should be repeated three times. Average all results to obtain a final
value.
RATE OF TRAVEL
TIME
MODE II
MODE III
High Speed
16.3 ±1.0 seconds
15.0 ±1.0 seconds
Low Speed
23.7 ±1.0 seconds
21.5 ±1.0 seconds
3M - 5M
(10' - 15')
20M (65' 7.5")
3M - 5M
(10' - 15')
HJA7002L
Figure 6