<How to adjust injection timing>
•
If upper pre-checked injection timing
degree is wrong, follow as below.
1) Loosen the fixing bolts(M8) of the
injection pump driving gear in
order to adjust the injection timing
slightly.
2) Turn the crank pulley clockwise
until V-groove of the flywheel
housing sight hole is aligned with
the injection timing degree of the
engine.
3) Coincide the mark on pointer provided in injection pump with the matching mark (FB) on
the flange surface of the drive gear by turning the flange in the oblong holes of the drive
gear.
4) Tighten the bolt (M8) to specified torque. (2.2kg.m) not to move the drive gear.
5) After confirmation that fastening bolts are completely tightened check the start point
(injection timing degree) of fuel delivery setting once more if not right repeat it again as
same as upper way.
9.3.25. Flywheel housing cover
•
Attach the gasket to the flywheel
housing cover.
•
Install the flywheel housing cover
and tighten the fixing bolts by zigzag
method.
9.3.26. Oil filter
•
Install the oil filter cartridge.
- 107 -
EBO4016I
EFM2072I