4.0 - OPERATION
4.1 - Pump Placement
Placement is an important step in safely operating this product.
1. Refer to diagram for proper placement instructions.
2. Ensure that the suction head is less than the discharge head.
3. Increasing the discharge head will decrease output.
4. Ensure pump is primed to minimize the suction head.
Suction head is the height to which a pump can raise water on the suction
side, measured from the water level in the sump. Discharge head is the vertical
distance between the intake level of the water pump and the level at which
it discharges water freely. Total head is the sum of the suction and discharge
head.
8