background image

FR-370G

QUICK

HIGH

MID

LOW

TEMP.

FR-370G

QUICK

HIGH

MID

LOW

TEMP.

FR-370G

QUICK

HIGH

MID

LOW

TEMP.

FR-4501..
FN-4501..

FRP-371..

FRP-372..

FRP-376..

JAN. 2013.

FR-4502..
FN-4502..

FR-4506..
FN-4506..

Summary of Contents for FN-4501 Series

Page 1: ...FR 370G QUICK HIGH MID LOW TEMP FR 370G QUICK HIGH MID LOW TEMP FR 370G QUICK HIGH MID LOW TEMP FR 4501 FN 4501 FRP 371 FRP 372 FRP 376 JAN 2013 FR 4502 FN 4502 FR 4506 FN 4506 ...

Page 2: ...s when replacing them 7 Make sure the hook is correctly engaged Remove dust and foreign materials from the housing and connecting parts 8 Do not fray damage machine heavily bend pull out or twist the power cord 9 Please check the evidence of moisture intrusion in the electrical components Replace the parts or mask it with insulation tapes if moisture intrusion was confirmed 10 Do not touch the ice...

Page 3: ...a R 600a Buyer No Gross Vol ISO15502 Total Freezer Refrigerator Storage Vol IS015502 Total Freezer Refrigerator Net Diemension Width Depth w o handle Height Electronic Part Fuse temp Fan motor 77 697mm 1801mm Heater Defrost control Sensor Fin Type Net Weight FRP 37 FRP 37 FR 450 408L 126L 282L 361L Automatic start stop Fan cooling system 99L 69kg FN 450 408L 126L 282L 361L 99L 742mm 697mm Automati...

Page 4: ...model dependent b Twist ice maker h Vegetable case Freezer Compartment Refrigerator Compartment a Freezer shelf g Refrigerator shelf e Shelf chilled case option k Jumbo pocket f Chilled Case option l Bottle Pocket c Freezer temperature control knob i Freezer pocket d Lamp window 15W x 1ea j Utility pocket l 2 ...

Page 5: ...l will change as follows Low Mide High Quick Low Freezer Refrigerator Low Mide High Quick Low Inner real temperature controlled by sensor on off point Each sensor on off point controls Compressor Fan motor operation Fan motor is on off after 1minute from compressor is on off Fan motor delay time is 1 minute 3 Quick Mode max time limit is 40 min When Quick mode selected led is on When refrigerator ...

Page 6: ... 8 10 24 hours Compressor runing ratio at every 2 hours is 85 in the room temperature is over 35 The room temperature affects the compressor runing ratio The degree is propotional to runing ratio Door opening time is over 2 minutes Total time Compressor is on time off time is 60 hours Any error happens 2 Defrost flow 4 ...

Page 7: ...D1 errror happens D1 defrost sensor is abnormal 80 minutes Maximum time limit Exit Defrost sensor is more than 10 Pause Control Compressor off Fan off Heater off Exit After 4 minutes Pre cool Heater is active Pause Fan delay Control Compressor on Fan off Heater off Exit After 4 minutes 4 Prevention of compressor restart Compressor doesn t restart for about 6 minutes to protect compressor regardles...

Page 8: ... 0 5 When the dial is MID step 3 Weak Ref SW1 is off The sensor off point is 1 0 When the dial is MID step Mid Normal on R31 31 4K 0 5 Dial SW1 Resistance value Sensor Off point Low Normal on R31 31 4K 3 0 Weak Ref off R31 R32 31 4K 2 15K 1 5 Weak Ref off R31 R32 31 4K 2 15K 1 0 High Normal on R31 31 4K 2 0 Weak Ref off R31 R32 31 4K 2 15K 3 5 Quick active for 40min Normal on R31 31 4K 3 0 Weak Re...

Page 9: ... is on off according to room temperature Error display Explanation Remark Low LED is flicker Mid LED is flicker R T 10 11 15 16 29 35 Comp on off 6 34 min 10 30 min 16 24 min 20 20 min Cause Defrost mode ends after limit time 80 minutes When evaporator is fully cover by frost or temperature fuse is abnormal or Heater is disconneted Action Need to check all defrost parts Cause After 2 hours compres...

Page 10: ...f test mode 1 How to start Push the TEMP button 30 times 2 How to exit Push the TEMP button 30 times again or After 21 hours automatically ends 3 Display All LED is on 4 Compressor freezer fan compressor cooling fan are on for 21 hours 9 A s Defrosting forced defrosting 1 How to start Push TEMP button 5 times while door is open 2 How to exit Push TEMP button 5 times while door is open again 3 Disp...

Page 11: ...Diagram 1 Wiring Diagram RSCR RSIR 9 ...

Page 12: ...Diagram 2 Air Flow Diagram 3 Refrigerant Cycle Diagram 10 ...

Page 13: ...Assembly disassembly 1 Freezer Louver 1 Remove screw cap on the Freezer Louver 2 Remove 2 screws 3 Take off the louver with driver as left figure shown 11 ...

Page 14: ... Refrigerator Control Box As 1 Take off lamp window as left figure shown 2 Disassemble refrigerator lamp 15Wx1ea 3 Unscrew which fixing the control box 4 Unscrew which fixing the control box 5 Take off the control box as 12 ...

Page 15: ... 7 3012101300 FOOT ADJ AS PP 2 1 1 EVA FIN SAS 8 3012911301 HINGE U AS PO T4 0 1 10 3011450200 COVER CAB BRKT PP 1 13 CORD POWER AS COUNTRY DEPENDENT 1 16 3013201700 HOSE DRN B PE FRB 5350NT 1 17 3012405820 GRILLE PCM B GRADE T0 4 1 19 3016805500 DRYER AS FRM P 371 1 20 3014434021 PIPE WICON AS FRM 37 1 22 3011801310 FAN C AS 110 FAN 3 17 SHAFT 1 23 Last page MOTOR C 1 24 3012004400 FIXTURE C MOTR...

Page 16: ...0 240V 15W 1 SHELF F 44 53 3 Option 1 LAMP AS 3013600020 220 240V 15W 53 4 3014800411 SENSOR R1 AS ABS 1 59 3015505200 WINDOW F LAMP PP 1 60 3011439500 COVER CUBIC DUCT HIPS 2 62 3018911600 LOUVER R S L AS FRM P 371 1 64 3018911700 LOUVER R S R AS FRM P 371 1 3017821800 GPPS MOLD 1 3017823110 GLASS NO PRINT 1 66 3011162300 CASE CHILD GPPS MOLD 1 3017822400 WIRE DECO 3017822000 GPPS MOLD 3017823010...

Page 17: ...S PVC 1 93 3011162100 CASE EGG GPPS FRM P 371 1 94 3019013100 POCKET SM HIPS FRP 371H 4 4501 series Hidden Handle 95 3012509600 GUIDE POKT ABS 1 96 3019013300 POCKET JUMBO HIPS SILK 1 97 3019013400 POCKET BOTL HIPS 1 98 3014229020 PANEL F CONTL AS FRP 371 1 98 1 3015505300 WINDOW FCP GPPS 1 98 2 3014228600 PANEL CONTL F ABS 1 98 3 3014301170 PCB F AS FRP 371 1 Some parts can be chaged for improvin...

Page 18: ...CASE EGG GPPS FRM P 371 1 94 3019013100 POCKET SM HIPS FRP 371H 4 4502 series Handle Packing 95 3012509600 GUIDE POKT ABS 1 96 3019013300 POCKET JUMBO HIPS SILK 1 97 3019013400 POCKET BOTL HIPS 1 98 3014229020 PANEL F CONTL AS FRP 371 1 98 1 3015505300 WINDOW FCP GPPS 1 98 2 3014228600 PANEL CONTL F ABS 1 98 3 3014301170 PCB F AS FRP 371 1 99 3014001801 PACKING HNDL AS FRP 372 3 1 Some parts can b...

Page 19: ...20 GASKET R DR AS PVC 1 4506 series Grip Handle 91 3012624400 HANDLE R ABS 1 92 3011611500 DECO R HNDL ABS 1 93 3011162100 CASE EGG GPPS FRM P 371 1 94 3019013100 POCKET SM HIPS FRP 371H 4 95 3012509600 GUIDE POKT ABS 1 96 3019013300 POCKET JUMBO HIPS SILK 1 97 3019013400 POCKET BOTL HIPS 1 98 3014229020 PANEL F CONTL AS FRP 371 1 98 1 3015505300 WINDOW FCP GPPS 1 98 2 3014228600 PANEL CONTL F ABS...

Page 20: ...V 60Hz 3015909800 AC 220 240V 3015906850 DC 10V Europe Taiwan Cuba R600a or unique country 27 COMPRESSOR 3953123R90 HEL23YG 9 1 110V 50Hz Jamaica 3956123S50 HPL23YH 5 3956123S50 HPL23YH 5 3956125S51 HPL25YH 5 K 3954125G50 HSL25YE 5 3953158J30 JX58LHE3 110V 60Hz 3956158J40 JX58LHP4 220V 60Hz 3956198M50 MQ98NAEM Europe R600a 220 240V 50Hz 3956151D20 MSA151 L1B Taiwan 28 SWITCH P RELAY AS 3018118150 ...