background image

9

EXPLANATION

Contact of safety switch Lid closing

Lid opening

Contact lever A

Normal (ON)

Position of
unbalanced load (OFF)

Automatic Unbalance Adjustment

Circulating-Water Course and Lint Filter

The alarm finished when you close the lid after opening
it. Check the unbalance of the wash load and the instal-
lation condition.

NOTES

Filter

Tub

Outer tub

Water
channel

Pulsator

This system is to prevent abnormal vibration during intermittent spin and spin process.

FUNCTIONAL PRINCIPLE

1

When the lid is closed, the safety switch

contact is “ON” position.

2

In case that wash loads get uneven during
spin, the outer tub hits the safety switch
due to the serious vibration, and the spin
process is interrupted.

3

In case that P.C.B. ASS’Y gets “OFF” signal

from the safety switch, spin process are
stopped and rinse process is started auto-
matically by P.C.B. ASS’Y.

4

If the safety switch is operated due to the

unbalance of the tub, the program is
stopped and the alarm is given.

CIRCULATING-WATER

The washing and rinsing effects have been
improved by adopting the water system in
which water in the tub is circulated in a
designed pattern.
When the pulsator rotates during the washing
or rinsing process, the water below the pul-
sator vanes creates a water currents as shown
in figure.
The water is then discharged from the upper
part of the tub through the water channel.
About 40 L/min. water is circulated at the ‘high’
water level, standard wash load and standard
water currents.

Summary of Contents for DWF-7094

Page 1: ...Service Manual Auto Washer Model DWF 7094 DAEWOOELECTRONICSCO LTD OVERSEASSERVICEDEPT ...

Page 2: ...1 WATER LEVEL CONTROL ELECTRONICAL SENSOR 12 ANTI NOISE PLATE O 13 GEAR MECHANISM ASS Y 14 LINT FILTER O 15 SOFTENER INLET O 16 FUNCTION FOR SOAK WASH O 17 ALARM SIGNAL O 18 RESIDUAL TIME DISPLAY O 19 AUTO WATER SUPPLY O 20 NEW WATER FLOW WATER FLOW FOR ADJUST THE UNBALANCED LOAD 21 FUNCTION FOR BUBBLE O 22 AUTO RE FEED WATER O 23 AUTO POWER OFF O 50Hz 400W 60Hz 430W 42 5Kg GROSS 48Kg 43 5Kg GROSS...

Page 3: ...nd turn off the power In case of the single valve model There is no hot water valve DRYTEN HOSEDRAINOAS NON PUMP COVER UNDER OPTION HOSEDRAINOAS PUMP WATER TAP ADAPTER HOSEDRAINCLAMP INLET HOSE CONNECTORINLET OPTION Accessories U P The parts and features of your washer are illustrated on this page Be come familiar with all parts and features before using your washer NOTE The drawing in this book m...

Page 4: ...table floor it could make considerable noise and vibration Installing Place N Ne ev ve er r i in ns st ta al ll l i in n t th he es se e p pl la ac ce es s 2Push the noise insulation plate into the end which decrease the noise made by this washer 1The packing box opened there is a noise insulation plate at the bottom of the back DWF 7094 8094 or front DWF 1094 2Check the Horizon Status Check the p...

Page 5: ... supplying between the hot maximum 50 C and cold water In using only one water tap or in case of attached one water inlet valve connect the inlet hose to the cold water inlet valve Do not over tighten this could cause damage to couplings FOR SCREW SHAPED TAP 3Insert the inlet hose adapter into the water inlet of a washer and turn it to be fixed Assert the packing in the inlet 1Connect the inlet ho...

Page 6: ... at proper time every 10 times of use Drain problem could be caused 3Return the filter as it was and insert the filter frame into the slot 1Pull the Filter frame upward 2Turn the lint filter inside out wash to the lint off with water 1Put down the remained water in the hose And put a container under the filter to collect water 2Turn the cap counter clockwise 3Pull out the filter assembly off the c...

Page 7: ...djust the Unbalanced Load It is a function to prevent eccentricity of the clothes after wash by rotating pulsator C W and C C W for 35 seconds But the SUIT course have no operation of the water currents to adjust the unbalnced load EFFECT It reduces vibration and noise effectively while spinning WATER FLOW Function for Soak Wash DISPLAY THE RESIDUAL TIME When the SOAK WASH is selected the total wa...

Page 8: ...educe the entanglement of laundry Draining Good draining The washer begins spin process after drainage condition Bad draining Draininig time is prolonged No draining Program is stopped and gives the alarm Drain Time Movement of the Program Less than Continue draining 15 minutes More than Program stops and gives the alarm with blinked on display lamp 15 minutes Pulsator System When the pulsator is ...

Page 9: ...itch due to the serious vibration and the spin process is interrupted 3 In case that P C B ASS Y gets OFF signal from the safety switch spin process are stopped and rinse process is started auto matically by P C B ASS Y 4 If the safety switch is operated due to the unbalance of the tub the program is stopped and the alarm is given CIRCULATING WATER The washing and rinsing effects have been improve...

Page 10: ...process When operation is finished the TIME INDICATOR will light up STRUCTURE FUNCTIONAL PRINCIPLE 1 When the DRAIN MOTOR connected to the power source the DRAIN MOTOR rotates with 900 r p m and revolves the pulley by gear assembly for reducing 2 When the pulley is rotated the pulley winds the wire to open the drain valve 3 Therefore rotation of pulley changed to the linear moving of wire 4 The wi...

Page 11: ...peed to prevent the damage to the small sized clothes Planetary gear Sun gear Internal gear Pulsator 1 revolution 5 revolutions Gear pulley V belt Gear unit as Motor Motor 1490 r p m 50Hz Gear Unit as Directly 1 5 Tub 640 r p m Pulsator 128 r p m Gear Pulley 640 r p m Gear Mechanism Ass y ...

Page 12: ...nd Gear Mechanism We changed the shape of the Lever because of preventing water leakage and noise of G M Please refer to the changing date as following table OLD type NEW type Valve Drain Assy G M with Tub O Part name Part Cord Specification Part Cord Specification Plate valve conn r 4509k78070 SECC Link valve drain 3617801900 POM Gear Mechanism 367305900 GM 8094 KS0X0 3617307610 GM 1300 KS6P0 367...

Page 13: ...ame Part Cord Specification Part Cord Specification Motor condenser 3964220620 110V 60Hz 3966221101 110 127V 60Hz W1D46CA012 DWF 8094 7094 3964720110 127V 60Hz 3964320160 220V 60Hz 3964321111 220V 60Hz W1D46UA012 3964010160 220 240V 50Hz 3964311311 220 240V 50Hz W1D46VA012 S Motor condenser 3964220420 110V 60Hz 3964221211 110V 60Hz W1D50CA012 S DWF 1094 3964820520 127V 60Hz 3964821311 127V 60Hz W1...

Page 14: ...AL OLD type NEW type Appearance Structure lead wire type terminal type Part name Part Cord Specification Part Cord Specification Switch safety assy 3619003100 SF 040A 3619003101 SF 030A CU T 14mm DWF 8094 7094 3619003110 SF 040F 3619003111 SF 030S CU T 9mm 3619003130 SF 041A DWF 8094PM 3619003131 SF 031A CU T 9mm Australia 3619003120 SF 040Z DWF 7094PM 3619003121 SF 030Z CU T 14mm Australia Switch...

Page 15: ... is inferior The load sensing is inferior After the load sensing operates about 15 seconds the message is displayed during 0 5 second and water level is always fixed high The water level sensing is inferior Install drain hose properly Remove foreign matter from drain hose Change drain motor Open the water tap Clean the water inlet filter Check whether or not is comes to the assigned water level Re...

Page 16: ...31 WIRING DIAGRAM APPENDIX è Wiring Diagram Dwf 7094 non pump ...

Page 17: ...32 WIRING DIAGRAM è Dwf 7094 Non Pump Single Valve ...

Page 18: ...33 WIRING DIAGRAM è Dwf 7094 Pump ...

Page 19: ...37 PARTS DIAGRAM è Parts Diagram ...

Page 20: ...38 PARTS DIAGRAM ...

Page 21: ...39 PARTS DIAGRAM ...

Page 22: ...40 PARTS DIAGRAM ...

Page 23: ...10 130V 50 60Hz HOSE 500mm 3618919400 AC 220 240V 50 60Hz HOSE 500mm A07 SENSOR PRESSURE 3614801110 1 D8T TERMINAL 5EP1048010 T5 V1 AC 110 130V A08 TRANS POWER 5EP1048020 1 T5 V1F 5EP1048030 T5 V2 AC 220 240V 5EP1048040 T5 V2F 3619003101 SF 030A CU T 14 187 7094 SWITCH SAFETY AS 3619003111 1 SF 030S CU T 9 187 7094CLE A09 3619003121 SF 030Z CU T 14 187 7094 AUSTRALIA A10 PLATE T 3614514800 1 ABS A...

Page 24: ...201 250V 315mA DWF 8094ME DUAL VALVE 3612727211 250V 315mA SINGLE VALVE HARNESS AS 3612727231 250V 600mA DWF 7094 3612727221 1 250V 315mA PUMP 3612727241 250V 600mA 3612727201 250V 315mA DWF 7094ME DUAL VALVE 3611302900 3x0 75 300x2 L 1800 CP 2PIN A25 CORD POWER AS 3611302800 1 A VCTFK 2x0 75 2 3M F 2PIN 3611302600 F H05W 3x0 75 2 3M ITALIAN 3PIN 3611303300 GTSA 3 3x0 75 GY ARGENTINE B02 HOSE DRAI...

Page 25: ...18957280 1 AC 220V 60Hz DWF 94PL 3618957250 AC 220V 50Hz DWF 94PN 3618957220 AC 240V 50Hz DWF 94PM B23 FILTER AS 3611901530 1 DWF 5590DPNF E TYPE PUMP MODEL B24 FRAME TOP 3612200100 1 PP C01 BALANCER AS 1 3616101700 DWF 7094 C02 FILTER 4505E82014 1 POLYESTER FILTER AS C03 FRAME FILTER 4505E82021 1 PP 4505E82002 C04 C05 SPECIAL SCREW 3616003700 24 SUS 5 5x16 C06 GUIDE FILTER AS 1 3612502400 DWF 709...

Page 26: ...R 3612757010 1 L 560mm D12 MOTOR SYNCHRONOUS 450ED45120 1 AC 110 130V 50 60Hz ST 23 3966010220 AC 220 240V 50 60Hz ST 23 D13 SPECIAL SCREW 3616007000 12 SCM24H 6 5x24 D15 BELT V 3616590220 1 M20 5 AGING 60Hz 3616590230 M21 AGING 50Hz D16 GEAR MECHANISM 3617307610 1 GM 1300 KS6P0 D17 BOLT HEX 7341801511 4 6B 1 8 15 MFZN D18 PROTECTOR GEAR 3618301300 1 SBHG1 1 6T D19 CUSHION DOWN 3611502700 2 P O M ...

Page 27: ...INAL 5EP1048010 T5 V1 AC 110 130V A08 TRANS POWER 5EP1048020 1 T5 V1F 5EP1048030 T5 V2 AC 220 240V 5EP1048040 T5 V2F A09 SWITCH SAFETY AS 3619008921 1 SF 030T TUBE T 0 5 187 3619008931 SF 030T TUBE T 0 5 187 AUSTRALIA A10 PLATE T 3614514510 1 ABS A11 CAP SOFTENER 3610907800 1 PP A12 NOZZLE DETERGENT 3618101700 1 PP A13 CASE DETERGENT 3611114700 1 PP A14 SPRING DOOR 3615107410 1 SUS304 D 1 8 A15 DO...

Page 28: ... SPG 0 5T B05 SCREW TAPPING 7112501411 1 T1TRS 5x14 MFZN B06 SUPPORT TUB BL 3615302210 1 SPG T1 4 B07 SUPPORT TUB BR 3615302310 1 SPG T1 4 B08 SUPPORT TUB FL 3615302410 1 SPG T1 4 B09 SUPPORT TUB FR 3615302510 1 SPG T1 4 3618921500 54 0µF 60µH L 470 110V 60Hz B10 ASSY CONDENSER 3618921900 1 41 6µF 60µH L 470 127V 60Hz 3618921000 13 5µF 60µH L 470 220V 50 60Hz 3618920800 11 4µF 60µH L 470 240V 50Hz...

Page 29: ... 184 PUMP MODEL D08 HOSE OVERFLOW 3613208901 1 PE LD L 280mm NON PUMP D09 VALVE DRAIN AS 3615408400 1 100M NON PUMP D10 BASE 3610387400 1 SECEN 2 0t D11 HARNESS EARTH INNER 3612757010 1 L 560mm D12 MOTOR SYNCHRONOUS 450ED45120 1 AC 110 130V 50 60Hz ST 23 3966010220 AC 220 240V 50 60Hz ST 23 D13 SPECIAL SCREW 3616007000 20 SCM24H 6 5x24 D15 BELT V 3616590220 1 M20 5 AGING 60Hz 3616590230 M21 AGING ...

Page 30: ...48 CIRCUIT DIAGRAM è DWF 7094 Circuit Diagram ...

Page 31: ......

Reviews: