8. PRESENTATION OF THE P.C.B ASS’Y
PRESENTATION OF THE P.C.B ASS’Y
27
MESSAGE CAUSE SOLUTION
Improper installation of drain hose.
The drain hose is blocked up by foreign
matter.
Drain motor or drain pump is inferior.
The water tap is closed.
The water inlet filter clogged.
It passes over the 60 minutes, yet it doesn’t
come to assigned water level.
Wash loads get uneven during spin.
Poor installation of the unit.
The lid is opened.
The safety switch is inferior.
The load sensing is inferior. After the load
sensing operates about 7 seconds, the
message is displayed during 0.5 second
and water level is always fixed ‘high’.
The water level sensing is inferior.
Install drain hose properly.
Remove foreign matter from drain hose.
Change drain motor or drain pump.
Open the water tap.
Clean the water inlet filter.
Check whether or not is comes to the
assigned water level.
Re-set wash loads evenly.
Proper installation.
Close the lid.
Change the safety switch.
Change the P.C.B. ASS’Y.
Check the water level sensor and the
contact part of the connector.
CONCERNING ERROR MESSAGE
Summary of Contents for DWF-178M
Page 32: ...PARTS DIAGRAM 31 PARTS DIAGRAM LEFT TOP FRONT...
Page 33: ...PARTS DIAGRAM 32 LEFT TOP FRONT...
Page 38: ...CIRCUIT DIAGRAM 37 CIRCUIT DIAGRAM 110V NON PUMP COLD ONLY...
Page 39: ...CIRCUIT DIAGRAM 38 CIRCUIT DIAGRAM 220V PUMP COLD HOT...
Page 40: ...CIRCUIT DIAGRAM 39 CIRCUIT DIAGRAM 220V PUMP COLD ONLY...