background image

48

DWD-E1211R: DOUBLE VALVE, BUBBLE

DWD-E1211R: DOUBLE VALVE, N/BUBBLE

7. Wiring Diagram

Summary of Contents for DWD-E1200R S

Page 1: ...SVCMANUAL DWD E1200R S DWD E1200W S DRUMWASHINGMACHINE 2005 09 DRUM WASHING MACHINE...

Page 2: ...ICATION OF DRUM WASHING MACHINE 6 3 VERIFICATION OF DRUM ASSY 7 4 PARTS LIST FOR EACH ASSY 8 5 SEQUENCE CHART OF PCB 23 6 TROUBLE SHOOTING 32 7 WIRING DIAGRAM 48 8 TROUBLESHOOTING REGARDING DRAIN 56 9...

Page 3: ...hnology Sterilizing up to 99 9 No damage and entanglement but excellent washability 4way savings noise vibration washing times energy Self cleaning course of Drum Good washing performance with heating...

Page 4: ...3 DD CONTROL DIRECT DRIVE SYSTEM BLDC MOTOR 3 THE DIRECT DRIVE SYSTEM OF DRUM WASHING MACHINE TUB DRUM LIFTER WASH BLDC DRAIN PUMP MOTOR...

Page 5: ...W ADDING CLOTHES LOCK HINGE DOOR AS GLASS GASKET 7 DRAIN PARTS DRAIN PUMP MOTOR VALVE HOUSING DRAIN HOSE I 6 DRY PARTS HEATER DRY OPTION BLOWER FAN FAN MOTOR BLDC THERMISTOR THERMOSTAT FUSE BI METAL C...

Page 6: ...B HARNESS NOISE FILTER POWER CORD 15A 2 DRIVE PARTS BLDC MOTOR DRUM BEARING SPIDER SHAFT TUB WEIGHT BALANCER 4 WASH HEATING WASH HEATER OPTION THERMISTOR 40 C FIXED TEMP CONTROL OPTION 60 C 90 C BOIL...

Page 7: ...4 1 GLASS DOOR 4 2 HINGE DOOR 4 3 DOOR LOCK S W 6 WASH HEATING WASH HEATER THERMISTOR 5 DRY DUCT B AS 2 PARTS for DRIVING 2 1 LIFTER AS 2 2 GASKET 2 3 WEIGHT BALANCER 2 4 ROTOR 2 5 STATOR 2 6 SHAFT 2...

Page 8: ...AS 7 2 HOSE DRAIN I 7 3 HOSE DRAIN 8 SUPPORTER 8 1 BASE U 8 2 DAMPER AS 3 70N 8 3 SPRING FRONT 2 BLACK REAR 2 YELLOW 5 3 3 3 2 1 2 2 2 4 3 4 1 4 2 2 3 7 2 7 1 8 1 7 3 8 2 1 1 1 3 2 1 6 8 3 EMP FUSE 3...

Page 9: ...E DRUMTYPE DRYTYPE Digitalcondensingdrysystem OPERATIONWATERPRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 NO PARTS NAME 1 FRME DOOR O 2 DOOR WINDOW 3 DCD STICKER 4 PANEL LOWER 5 CABINET FRONT 6 PANEL LOWE...

Page 10: ...7 3 VERIFICATIONOFDRUM ASSY...

Page 11: ...7...

Page 12: ...1 FRAME PLATE F 3612204400 HIPS 1 A02 FRAME PLATE REAR 3612204500 HIPS 1 A03 PLATE TOP 3614531600 WOOD 1 A04 PAD CUSHION 3614110500 SPONGE 1 A05 FIXTURE PLATE T 3612007100 STAPLE 8x10 1 SCREW TAPPING...

Page 13: ...BUTTON FUNCTION 3616602700 ABS UV_BASE 1 SCREW TAPPING 7121301508 T2S PAN 3x15 MFNI 3 B10 WINDOW DISPLAY 3615502700 ABS TR558 1 B11 DECORATOR WINDOW 3611630800 ABS GILDING_BASE 1 B12 HOLDER POWER 361...

Page 14: ...DOOR OPEN 3616603200 ABS 1 B07 BUTTON FUNCTION 3616603000 ABS 1 SCREW TAPPING 7121301208 T2S PAN 3x12 SUS 3 B08 HOLDER LED COURSE 3613049300 ABS 1 B09 HOLDER LED CUSTOM 3613049200 ABS 1 B10 CASE PCB...

Page 15: ...ABS 1 B02 HOLDER LED COURSE 3613049500 ABS 1 B03 HOLDER LED CUSTOM 3613049200 ABS 1 B04 CASE PCB F 3611139900 HIPS 1 B05 PCB PRPSSW4D10 1 SCREW TAPPING 7122401411 T2S TRS 4x14 MFZN 3 B06 DECORATOR FIL...

Page 16: ...12 3 CABINETFAS...

Page 17: ...00 PP 1 C09 STOPPER DOOR 3615202300 PP 3 C10 SCREW TAPPING 7122401608 T2S TRS 4x16 SUS 2 C11 SCREW TAPPING 7115402008 T1S FLT 4x20 SUS430 NATURAL 15 C12 DOOR GLASS 361A110600 GLASS DWD 100DR 1 C13 PRO...

Page 18: ...6 L 165mm 2 PRE WASH D11 HOSE A 3613266600 EPDM ID 10 OD 16 L 335mm 1 MAIN WASH D12 HOSE B 3613266700 EPDM ID 10 OD 16 L 420mm 1 HOT D13 CLAMP SPRING 3611203800 ID 15 5 T 0 6 B 10 8 D14 VALVE INLET 36...

Page 19: ...15 5 DUCT DUCTPIPEAS...

Page 20: ...612204100 SBHG 1 0T 1 E10 DUCT B THERMOSTAT 361A200100 AL 1 E11 PACKING THERMOSTAT 3614009900 SILICON 1 E12 SWITCH THERMOSTAT 3619046500 ON 120 C OFF 150 C 230V 1 E13 HEATER DRY 3612800900 220V 210W 2...

Page 21: ...17 6 CABINETAS...

Page 22: ...3512204200 SBHG 1 2T DWD 100DR 1 F11 HOSE DRAIN I 3613269500 ST EL 840M 1 F12 CUFF DRAIN HOSE 3616802600 PP PUMP 1 F13 HOSE SIPHON 3613269600 EPDM 1 F14 CLAMP HOSE 3611204700 D 27 1 F15 CORD POWER AS...

Page 23: ...19 7 BASEUAS...

Page 24: ...1910 PP DWD 100DR 1 G04 UNIT FILTER EMI K19 3611908000 220V FUSE250V 471 474 10MH 1 3611908010 100V FUSE125V 471 474 10MH 1 G05 SUPPORTER LEG 3615303600 PO 3 0T 4 G06 FIXTURE LEG 3612006400 ABS DWD 10...

Page 25: ...21 8 TUBAS...

Page 26: ...PP PUMP 1 H16 HOSE DRAIN 3613269000 EPDM PUMP 1 H17 AIR TRAP AS 3610AAR101 110RP HOSE TRAP 1 H18 SPRING SUSPENSION R 3615113600 BLACK 2 H19 GASKET TUBE 3612321100 EPDM FORM 1 H20 WATER SEAL 361A600100...

Page 27: ...in 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 1 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water...

Page 28: ...1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 1min 7min Mid Spin 5min 3min Crease care 60sec Dry 15min 10min Cooling 5min END 10sec Crease care 30min...

Page 29: ...g the same 45 rpm with left and right direction alternatively 2 Attaching stop Attaching the laundry to drum inside with constant speed 3 Unbalance checking point First step check the U B at 95 rpm 16...

Page 30: ...sec pulse until unlock 3 After door locking all parts can work normally 4 After pressing power button if the temperature of wash thermistor is over 50 C or the water level is over the safety level the...

Page 31: ...isplay LOCK off Dooropen drain fanmotoron coldwatersupply waterlevelis lessthansafetylevel NO NO YES YES Temperatureis lessthan50 C 2 DOOROPENSYSTEM 1Ifaddthelaundryduringwashing pressthedoorunlockbut...

Page 32: ...mode press TEMP and DRY simultaneously 2 5 The sequence of drain 1 If the checking time to reset point is below 1 min the remaining drain time is 30 sec 2 If the checking time to reset point is over...

Page 33: ...rnon LOCK signal allprocessisconductingnormaly 2Whenworkingstarts thePCBdisplaysallthesensorconditions 3Inthiscase BLDCMotorisnottested Inordertotestit selectspinorrinse 2 Continoustestingmode 1 Proce...

Page 34: ...ressure is inferior sensor pressure The drain motor dose not work Change the drain motor The drain motor is an inferior product or broke down The fan motor does not work Change the fan motor The fan m...

Page 35: ...istor wash The water temp is over 45 C in delicate wool course Change the thermistor wash The heater wash dose not work Change the heater wash The water temp doesn t rise over 2 C during 15min The hea...

Page 36: ...y assembled Openthewatertap Cleanthefilter ChangetheInlet Valve Thecontactofthe Connector ChangetheInlet Valve ChangetheSensor Pressure Changethebad parts ChangetheInlet Valve ChangetheInlet Valve IE...

Page 37: ...heckthehosecondition checktheconnectorcondition frequencyCheck refertobelow connectorbroken Checkingmethodofcoilregistance harness connector E2 overflowerror Waterlevelishigherthanoverflowlevelbecause...

Page 38: ...CloseDoorsecurely ReplaceDOORAS ReplaceDOORS W AssembleConnector InsertReceptacleno 2 orno 3 ReplaceDOORS W Afterdrainingwater openthedoor LE LE LE LE LE LE LE checkthejoiningstatusof connectorbyeye T...

Page 39: ...35 2 CheckingmethodofDOORLOCKSWITCH 3 CheckingmethodofDOORLOCKSWITCH 2345 Nono 1 BetweenNo 3 No 4 if156 234 itisnormal BetweenViloetandBluewire If156 234 itisnormal PIN array...

Page 40: ...the resistancebetweentwoendsis23 3 25 7 Checkwhetherdisconnectedornot SeeFig A Measuretheresistanceoftwoendsofthesensor if 11 981K atR25 itismormal Measuretheresistanceoftwoendsofthesensor if 11 981K...

Page 41: ...orDryOPEN SHORT 2 H2 ThermisterWashOPEN SHORT 3 H3 DryOverheating SensingTemp isover125 4 H4 WashOverheating SensingTemp isover95 5 H5 Wash Overheating InWool Lingeriecoursessensingtemp isover45 6 H6...

Page 42: ...rivingmechanismofBLDCMOTOR BLDCMOTOR MagneticdensityflowofBLDCMotor SequencediagramofBLDCMOTOR 5 MOTOR Rotor Insulator Core Insulator electromagnet generatinghighpowerbyrotator apermanentmagnet andsta...

Page 43: ...Y SYSTEM F H I A B C D E G J DIVISION PARTSNAME A DUCTCOVER B FANMOTOR C HEATERDRY D DUCTBUNDER E VALVEINLET DRY F THERMOSTAT Bie METAL G THERMISTOR H DUCTBUPPER I FANAS J FUSETEMPERATURE 6 DRY SYSTEM...

Page 44: ...ONDENSINGDUCT andcondensedinDUCTcontactingWATERSUPPLY condensedwater isextractedthroughDRAINHOUSING Dryfunctionisperformedbycontinuousrepetitionofevaporatingandcondensingcirculationasabove DRY DUCT T...

Page 45: ...reis87 COn 95 COff dryingtimeis166min STRONG Heatercontroltemperatureis87 COn 95 COff dryingtimeis216min SELECTINGTIME Heatercontroltemperatureis87 COn 95 COff customercanselectthedryingtimeas 1Hr 2Hr...

Page 46: ...ngtheairtemperature FAILUREMODE Theaircannotbeheatedeventhoughwaterissupplied H1 shotorcut off H3 airtemp isreachedover150 C CHECKINGMETHOD Checktheresistanceofthermistor replacewithnewone FUSETEMPERA...

Page 47: ...50 C andreoperatingheater byconnectingheaterpowersupplyifthetemperaturefallsunder120 C OPERATINGTEMPERATURE PICTURE UNITFANMOTOR function circulatingtheinsideairduringdryprocess SPEC PICTURE FAILUREMO...

Page 48: ...redrayfromceramicparticlecoatingonDUCT BUPPER principle DUCT B UPPER FAR INFRAREDCOATING DUCT B UPPER heatedair emitfar infrared f a r i n f r a coatingarea steilization The far infrared ray is emitte...

Page 49: ...onebeforethedryhadstarted Situation PCBshows H1 or H3 cause Thermistorisbroken Thermistorisshortorcut off countermeasures replacetheThermistor part name checking point checking results jurge repair me...

Page 50: ...yheater replacetheFusetemp checking point part name checking results repaire method HEATER SENSORTEMP FUSE TEMP dryHeaterisshortorcut off Thermistorisshortorcut off FUSETEMPERATUREiscut off replacethe...

Page 51: ...ure replace fanmotor 1DisassembletheDUCTASfromDUCTBAS SCREW4EA 2DisassembleFANASfromDUCTCOVERASbyusing L wrench 3DisassembleFANMOTOR SCREW3EA DUCT COVER AS 2 5mm L wrench parts Control time MOTOR 10 s...

Page 52: ...48 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE 7 Wiring Diagram...

Page 53: ...49 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE...

Page 54: ...50 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE...

Page 55: ...51 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE...

Page 56: ...52 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE...

Page 57: ...53 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE...

Page 58: ...54 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE...

Page 59: ...55 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE...

Page 60: ...ngdrainduring10min ThewaterlevelcannotreachtoRESETPOINTduring10minofdrain Checking Methods Check the hose drain O condition twisted or frozen Check the hose drain O condition blocked DRAIN MOTOR is br...

Page 61: ...AS by turning CCW direction Please keep FIXTURE UP DOWN AS for later use When fixing FIXTURE UP DOWN AS turn it CW direction PARTS NAME FIXTUREUP DOWNAS UNIT SERVICE WRENCH LEG ADJUST AS REMARKS SPECI...

Page 62: ...ingLEGADJUSTAS Adjusting Method Remarks If turned CW the LEG ADJUST AS moves the washer upward If turned CCW the LEG ADJUST AS moves the washer downward 5Afteradjustinglevel fixSPECIALBOLT Adjusting M...

Page 63: ...ingconditionbetween fixtureheateristight littlegaponleft right Atfasteningthenutforfixingtheheaterwash keeptheprotrusionlength ofboltto10 12mm ifunder10mm watercanleak andifover12mm fixtureheatercan d...

Page 64: ...2005 09 DRUM WASHING MACHINE 686 360 8282 http www dwe daewoo co kr...

Reviews: