Daewoo DGB-100MSC Installation And User Instructions Manual Download Page 1

INSTALLATION AND
USER’S INSTRUCTIONS

MODEL NO. DGB-100MSC/130MSC/160MSC/200MSC

DGB-250MSC/300MSC/350MSC/400MSC

Summary of Contents for DGB-100MSC

Page 1: ...INSTALLATION AND USER S INSTRUCTIONS MODEL NO DGB 100MSC 130MSC 160MSC 200MSC DGB 250MSC 300MSC 350MSC 400MSC...

Page 2: ...50MSC 400MSC General Description Power Plug Air supply duct Dual pipes type Gas flue duct Co axial or Dual pipes type Air supply duct Co axial pipes type Emergency switch Room controller connector Eme...

Page 3: ...to indicate a potential hazard situation which if not avoided could result in death or serious injury Used to indicate a potential hazard situation which if not avoided may result in minor or moderate...

Page 4: ...evice to turn on the pump and the burner if necessary Do not use the boiler for any other purpose than for heating and hot water If used for drying clothes it may result in fire Hot water from the boi...

Page 5: ...weight of the boiler The boiler may be installed on a combustible wall subject to the requirements of the Local Authorities and Building Regulations Warning Check flue gas venting system Visually insp...

Page 6: ...burns Installation or repair work must be done by a qualified boiler installer or service techinician Failure to comply could result in severe personal injury death or substantial property damage Do n...

Page 7: ...ler plugged in at all times When plugged in the boiler s anti freeze function maintains a minimum temperature to prevent the pipes from freezing The pipes connected to the boiler must be insulated usi...

Page 8: ...d hot water Week button When you need hot water quickly press this button and you can change a day of the week when you press this button again Going out button When you are away press this button to...

Page 9: ...en the Rapid hot water function is selected Going out indicator Shows when Going out anti freezing mode is selected Current time display Shows the current time Heating timer indicator Scheduled times...

Page 10: ...ter Press Hot water button to turn Hot water mode on press Heating button for turn off Hot water only When using Hot water only 1 Use Hot water mode when heating is not needed 2 The boiler comes into...

Page 11: ...temperature Using Room temperature Press Heating water Room temperature select button Notes This boiler uses a propotional control method designed to adjust the flame according to the difference betwe...

Page 12: ...rops to a certain point the minimum operation mode begins and the pump rotates water to prevent the pipes from freezing to burst The Anti freezing mode is not operative if there is no water in the boi...

Page 13: ...er button for a couple of seconds The setting time and week are displayed when you turn on Room controller Caution After a power outage the current time of Room controller will be worked by internal b...

Page 14: ...ite the boiler operates and controls by a selected temperature in Room or Heating water And when using Heating timer the programmed times are marked in black the boiler operates by Heating timer 2 Hea...

Page 15: ...button To use the boiler select on otherwise select off Heating water temperature selection button When it is on heating water temperature lamp is on and display heating water temperature and the boi...

Page 16: ...n button is off Heating temperature adjusting You can adjust the room temperature black color Heating water temperature display Shows the setting or current heating water temperature Heating water tem...

Page 17: ...eating mode only when not using hot water Hot water only 1 In summer only to use hot water not to use heat the room 1 Heating temperature setting 2 Hot water temperature setting Select Heating Hot wat...

Page 18: ...ontrol method designed to adjust the flame according to the difference between the set temperature and the current temperature The table below shows the temperature differences which will cause either...

Page 19: ...peaple use hot water at the same time in a different place the water may not be hot enough although you have the hot water to High H This is because the amount of the water you use exceeds the capaci...

Page 20: ...freezing Leave the boiler plugged in all the time If you have not used the boiler for a long period of time the pump may not rotate In the event of this turn the inside groove clockwise 3 to 4 times w...

Page 21: ...ssure level In this case you pull the pressure relief valve upward and it sends out the water until the pressure falls below 2kgf cm Low pressure of heating pipes may disturb the circulation of heatin...

Page 22: ...er Is the distributor valve open Ensure that one of the distributor valves is open After checking the above turn the power off and on There is a smell of exhaust gas during combustion Ensure the flue...

Page 23: ...5 Pull the pin of the filter upwads to separate 6 Pull the filter downwards to separate Beware of any possible remaining hot water Caution 7 After cleaning assemble the filter following the above ste...

Page 24: ...be handed to the customer The user must be educated by the installer on how to use the boiler After installation the manual must be kept with the user Caution Before installing the boiler Check the ga...

Page 25: ...g and servicing the boiler more than 30cm more than 60cm more than 30cm The boiler must not be fitted on a combustible wall surface In case the wall surface is combustible attach incombustible materia...

Page 26: ...20A Heating water out 20A Heating water in 15A Water in 15A Hot water out 15A Gas in 20A Gas in Equal to left Equal to left Equal to left Equal to left Power supply AC 220V Connect the pipes using uni...

Page 27: ...upply pump is needed do not install the pump in the boiler room The pump s automatic function can cause a fire in the case of a gas leak Install a shut off valve at the water intake point Hot water pi...

Page 28: ...ter of flue duct 80mm slope 3 o above 60cm above 15cm above 15cm above 50cm outlet for ventilation incombustibles air inlet Install a terminal guard to protect the terminal from mechanical damage from...

Page 29: ...ards on the walls to prevent fire The ducts should be placed at a point at which you have easy access for maintenance If due to unavoidable circumstances you must install them in the roof space or a c...

Page 30: ...ntal projected area of the gas flue duct mm Figure 1 K factor Figure 2 Proportion of simultaneous use of boilers When the cross sectional area is circular When the cross sectional area is square When...

Page 31: ...alling the appliance in accordance with the recommendations made herein are the installer s responsibility Check if all the components listed below are in the chimney box Components Q ty Cautions for...

Page 32: ...wire band Insert the air socket to the gas flue duct until you hear a click sound Put the air supply hose to the air duct and affix them with the wire band Air supply hose Wire band Wire band Gas flu...

Page 33: ...wall holder Elbow Insert Chimney to the gas flue duct and the ait duct Affix Chimney with Steel bands tightly Steel band Gas flue duct Air duct 4 Installing in the wall Attach the interior wall holder...

Page 34: ...0L to Boiler s Duct in flue 80 and Duct out flue 80 as an above right picture 2 Assembly of Co axial pipes type Chimney DGB 80C Diameter of Air supply duct 110mm Diameter of Gas flue duct 80mm Steel b...

Page 35: ...35 Complete sets of Co axial Chimney EURO Elbow Terminal Top Extender Standard set...

Page 36: ...4 1 2 3 4 80mm 110mm 1 2 Connection pipes Heating water in Heating water out Water in Hot water out Gas in Gas flue duct Air duct Dimension 3 4 3 4 1 2 1 2 80mm 110mm 1 2 Model No Connection pipes He...

Page 37: ...erly There is no or in the room controller cable Insulate the connections with insulating tape to prevent a shortcut separation or a fault current Mounting the Room controller Separate the holder from...

Page 38: ...ress the Heating Water Temperature Room Temperature Heating buttons at the same time 3 appears on the display when the boiler conducts a test run Open the distributor valves one at a time and let out...

Page 39: ...d line of the gas leak detector to the white line of the circuit board Connect the black line of the gas leak detector to the white line of the circuit board Make sure the white or red line must be co...

Page 40: ...of gas pressure 1 2 5kPa 10 25mbar Gas input max Heating Hot water LPG LNG LPG LNG 12 7kW 1 0kg h 12 7kW 1 14m h 3 16 8kW 1 33kg h 21 1kW 1 67kg h 26 5kW 2 1kg h 16 8kW 1 52m h 21 1kW 1 9m h 26 5kW 2...

Page 41: ...50Hz Electrical input 110W 130W Size WxHxD 490 x 626 x 369 mm Weight 33kg 36kg Duct diameter Air inlet 110mm Gas flue 80mm Piping Gas Water in Hot water out Heating water in Heating water out Safety...

Page 42: ...Daewoo Gasboiler Co Ltd...

Page 43: ......

Page 44: ...MSC1110 EN W21...