www.daewoopower.bg
6
EN
4
- After the power switch on, start priming procedure immediately.
- When the priming is not successful, air may be remained in the suction pipe. Then, to remove air in the
suction pipe, pour water and power on and off repeatedly.
- Because the pump has no switch, use power switch on the wall or plug in and out from the receptacle.
9. TOTAL HEAD-CAPACITY CURVE
10. SPECIFICATIONS
11. TROUBLES AND COUNTER-MEASURES
Model
Autojet 80s
Autojet 100s
230V-50HZ
230V-50HZ
550 W
750 W
Voltage
Frequency
Power
28 M
28 M
Max height
42 l/min
60 l/min
8 M
8 M
Max flow
Max
suction
1”
1”
Suction
diameter
1”
1”
Discharge
diameter
20°C
20°C
Liquid
temperature
40°C
40°C
Max
temperature
H
H(m
m))
00
1100
2200
3300
4400
10
20
30
40
50
Q(LIT/MIN)
60
5500
2
1
Troubles
Causes
Counter-Measures
(The indication can be done by user.)
Faulty cord connection.
Thermal protector.
If the motor is overheated, it does not operate.
Then, wait till getting cold(20~30 minutes)
Insert the plug securely.
Cord disconnected.
Replace the new cord.
Trouble in motor.
Repair or replace the motor.
Tool low power supply voltage.
Consult with the power supplies compare.
Water level of well is lower than standard level.
Trouble in foot-valve.
Check the water level of well.
Clean the foot-valve, the foot-valve seat
and the foot-valve hole.
Air drawn into suction pipe.
After checking the joints of piping, shut
them perfectly.
Air drawn into pump from mechanical seal. Replace the new mechanical seal.
Too low or high power supply voltage.
Consult with the power supplies compare.
Impeller is in contact with another part.
Repair the defects.
Short or open circuit of the capacitor.
Replace the capacitor.
Air drawn into suction pipe.
Repair the defects of pipe.
(To prevent air leaking.)
Water leaks at pipe or pump.
Repair pipe, pump parts and faucets etc.
Water leaks at mechanical seal.
Repair the mechanical seal.
Foot-valve does not shut perfectly.
Clean the foot-valve.
Air drawn into suction pipe.
Repair the defects.
Motor does not start.
Water in not pumped out
although motor runs.
Thermal protector for motor
works too often.
Water does not come out at the
first few minutes after switch on.
Pump starts though no water
is being used.
Water does not come out
immediately after switch on.
1- AUTOJET80S
2- AUTOJET100S
3000 L/H
3600 L/H
Summary of Contents for AUTOJET80S
Page 2: ......
Page 7: ...www daewoopower bg 7 EN...
Page 9: ...www daewoopower bg 9 BG 1 2 40 0 40 10 3...
Page 10: ...www daewoopower bg 10 BG 4 8 1 5 bar 1 2 bar 5 6 8 max 9 7 230 V 50 Hz 1 2 1 5 3 N L 4...
Page 12: ...www daewoopower bg 12 BG 11 20 30...
Page 13: ...www daewoopower bg 13 BG 12 E...
Page 17: ...www daewoopower bg 17 BG 24 13 1 12 6...
Page 19: ...www daewoopower bg 19 BG...
Page 20: ...www daewoopower bg 1784 1 51 359 2 81 77 600 359 2 81 77 601...