1.  PRECAUTION BEFORE USING THE PUMP

1. Connect the earth wire before use.

This enable you to prevent an accident caused by electric shock when the electric insulation is not in order.

For your safety from the danger of electric shock, please be careful not to get power plug stained with water.

2. CAUTION IN CONNECTING THE EARTH WIRE

Connect the earth wire after turning off the electric power.

Never connect with gas pipes, other wire it can be the cause of explosion.

2 .Avoid operating under the condition of dry running and delivering no water.

For it will shorten the service life of pump and also cause the trouble of motor.

3. Never wrap the motor or the pump head in a blanket or a cloth for preventing freezing in the cold weather.

4. Avoid using the pump under the condition of ambient temperature over 40

°C

and below 0

°C

, and also

with hot water over 40

°C

.

For it will shorten the service life of pump.

5. Be careful not to use the pump with other liquids except for water.

When this used for solvent such as benzol, acid, in flammable liquids such as gasoline and highviscous 

liquid, there is a risk of the fire and it will cause the trouble of the pump and also shorten the service life of it.

6. Avoid using the pump under the condition exposed to the direct rays or rain because it will be the reason 

of shortening the service life of the pump and also of the danger of electric shock.

7. When this pump is set up in the well, which is easy to suck in sand, above all, sand filter is needed.

For it will prevent the defacement of the impeller in the pump head for a short time, the decline of pressure 

and the decrease of pumping water.

8. The permitted voltage of this pump is 10% of the rated voltage. Otherwise it will be the reason of shorte-

ning the service life of the pump.

9. Never operation the pump without priming waters, for it will damage the mechanical-seal and the impeller 

and shorten the service life of the pump.

• Before setting the power on, confirm no abnormality by manual operation (exam by driver) of the truly ope-

rating act 2-3 times in checking of dust or sand is put into the pump and also adhesion of impeller or mecha-

nical-seal.

3.  WHEN THE PUMP IS REUSED AFTER A LONG TIME

There is possibility for the motor not to be operation in the condition of switching on the electric power, 

because of the sticking and solidification of the dirt and filth in the water of the pump head.

In that case, turn off the electric power, and then turn the shaft in the back of the motor a few times with 

driver or something like that. After that, you can operation the pump as usual.

0201

32012

62011

62012 62013

52012

52013

32013

0202

0203

1303

53032

53034

83034

1304

73036

83033

53037 93035

03031

03041

62014

62015 62016

42031

42032

42032

42033

43034

0501

43035

33032

5401

Pasi

Kgf

  4

  5

   

  

3

6

2  1

  0

0204

63011 63012 63013 63014

3

4. CHECKING POINTS BEFORE INSTALLATION

- Install the pump just over the well as possible as you can.

- But when the pump must be installed away from the well because of the circumstances, the maximum 

distance of the pipe from the well to the pump is limited according to the suction lift.

- Decide the suction lift considering the dry seas.

5. GUIDE FOR INSTALLATION

- Concrete the foundation with cement that the pump may not lean or slant even after many years.

- Select the place where the pump can be conveniently checked or repaired after installation.

- Install the stop valve on the dishrag side of the pump and it will be very convenient for checking and repai-

ring the pump.

- Minimise the number of the elbows to prevent the water leaking in the piping or to lessen the resistance of 

water.

6. HOW TO OPERATION THE PUMP

- This pump is not self-priming type, should be installed foot-valve to the bottom of suction pipe.

- Measure the depth from the ground surface to that of the well. The suction head is standardized at 8 m 

(max. 9m).

- Be sure to use pipe of standard diameter for normal.

7. CONNECTION METHODS FROM POWER

- When the pump is sending out from the manufacture, it is set for 110V/60Hz.

- Check the voltage of the electric power before operating the pump.

- Warranty does not include accidents due to incorrect installation. See your electrician for advice. It is recom-

mended to have a protected motor circuit breaker near the pump. It will cut power in case of surcharge, bloc-

king or missed.

- Take terminal box cover off.

2. Drive the 3 wires electric cable through opening (minimum section 1,5 mm ).

- Connect 2 wires to terminals N and L. Connect earth wire (green/yellow) to terminal located under terminal 

block, marked with symbol. On figure.

- Put cover back.

roti

ca

pa

C

220V/60Hz

110V/60Hz

roti

ca

pa

C

C

RD

BK

BL

Note:

BK: Black

BL: Blue

RD: Red

220V/60Hz

C

RD

BL

110V/60Hz

Note:

BK: Black

BL: Blue

RD: Red

BK

Connection methods from power 

Electric principle diagrams

8.  HOW TO START THE PUMP

Since this pump has no self-priming system, at the start of operation, make priming by the following

sequence:

- Be pulled out with the water.

- Before the power switch on, the water cock of the discharge side should be opened.

- After the power switch on, start priming procedure immediately.

- When the priming is not successful, air may be remained in the suction pipe. Then, to remove air in the 

suction pipe, pour water and power on and off repeatedly.

- Because the pump has no switch, use power switch on the wall or plug in and out from the receptacle.

Summary of Contents for AUTOJET80S

Page 1: ...AUTOJET80S 100S END SUCTION PERIPHERAL PUMP USER S MANUAL Manufactured under license of Daewoo International Corporation Korea Daewoo International Corporation Korea...

Page 2: ......

Page 3: ...tion before using the pump 4 Checking points before installation 5 Guide for installation 3 6 How to operation the pump 3 7 Connection methods from power 3 8 How to start the pump 4 9 Total head capac...

Page 4: ...of shortening the service life of the pump and also of the danger of electric shock 7 When this pump is set up in the well which is easy to suck in sand above all sand filter is needed For it will pre...

Page 5: ...ead is standardized at 8 m max 9m Be sure to use pipe of standard diameter for normal 7 CONNECTION METHODS FROM POWER When the pump is sending out from the manufacture it is set for 110V 60Hz Check th...

Page 6: ...epair or replace the motor Tool low power supply voltage Consult with the power supplies compare Water level of well is lower than standard level Trouble in foot valve Check the water level of well Cl...

Page 7: ...www daewoopower bg 7 EN...

Page 8: ...www daewoopower bg 8 BG 1 9 2 9 3 9 4 10 5 10 6 10 7 10 8 11 9 11 10 11 11 12 12 13 13 15 14 16...

Page 9: ...www daewoopower bg 9 BG 1 2 40 0 40 10 3...

Page 10: ...www daewoopower bg 10 BG 4 8 1 5 bar 1 2 bar 5 6 8 max 9 7 230 V 50 Hz 1 2 1 5 3 N L 4...

Page 11: ...www daewoopower bg 11 BG 8 3 9 10 Max L H W V Hz r p m AUTOJET80 3000 8 550 230 50 2850 1 1 AUTOJET100S 3600 8 750 230 50 3450 1 1...

Page 12: ...www daewoopower bg 12 BG 11 20 30...

Page 13: ...www daewoopower bg 13 BG 12 E...

Page 14: ...14 BG 0201 0203 0204 42031 32012 1303 62011 03031 62012 33032 62013 53032 63011 03041 63012 1304 63013 43034 63014 5401 52012 0501 32013 53034 52013 53037 62014 93035 62015 73036 62016 83033 0202 8303...

Page 15: ...2100 2010 EN60335 1 2012 A11 2014 AC 2014 EN60335 2 41 2003 A1 2004 2 2010 EN62233 2008 AC 2008 EN55014 1 2006 A1 2009 A2 2011 EN55014 2 2015 EN61000 3 2 2014 EN61000 3 3 2013 Directives 2006 42 C Mac...

Page 16: ...www daewoopower bg 16 BG 361 0893 383 798 53 056 859660 275 052 575400 248 032 946065 42 082 870104 37 042 600699 5000 062 690003 90 064 600082...

Page 17: ...www daewoopower bg 17 BG 24 13 1 12 6...

Page 18: ...www daewoopower bg 18 BG 13 1 115 112 112 115 115 112 1 112 2 1 2 3 1 113 2 3 2 114 4 5 1 114 113 1 2 2 3 115 4 1 115 2 1 3 1 1...

Page 19: ...www daewoopower bg 19 BG...

Page 20: ...www daewoopower bg 1784 1 51 359 2 81 77 600 359 2 81 77 601...

Reviews: