background image

PLANNING

GUIDE

www.Dacor.com        Phone: (800) 793-0093

All specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

CI.12

Stiffener

Cabinet face

Countertop

Floor

3/8” Min. (10 mm) space 

behind raised vent 

chassis to clear stiffener

3/8” Min. (10 mm)

flat countertop overhang

required behind cutout

ERV or PRV series raised 

vent: Check raised vent 

dimensions/specifications 

to determine proper fit

 SGM Series Cooktop

rGC/sGm series Drop-In Gas Cooktop 

with Erv/Prv series raised vent

CombINATIoN INsTALLATIoNs

Document # PGCI-008

Revised 05/07/09   Page 1/2

 WARNING

Observe all governing codes and ordinances during 

• 

planning and installation. Contact your local building 

department for further information.
All appliances must be installed in accordance with the 

• 

accompanying installation instructions.

All tole1/16” -0 (+1.6 mm, 0) unless otherwise noted

Cutout Dimensions

Side View - RGC/SGM Series Cooktop with

ERV/PRV Series Raised Vent

IMPORTANT: 

Be careful to use the correct cutout diagram (on page 2/2) to determine the countertop dimensions. Carefully double check 

all dimensions against the table below and the correct diagram before cutting the countertop.

* Total cutout depth, accommodates both the cooktop and raised vent  

** 

IMPORTANT:

 Notch depth is included in total cutout depth (D). 

DO NOT

 add notch depth to total cutout depth (D).

RGC or SGM series cooktop

Countertop Dimensions 

Installation Type

Cutout  

Diagram

C (minimum)

D

E

F

G

H

RGC/SGM304 with 

ERV30 or PRV30

Figure 1

(Square)

3/8”

(10 mm)

22 1/2” * 

(572 mm)

27 3/4”

(686 mm)

NA

NA

NA

RGC/SGM365 with 

ERV36 or PRV36

Figure 1

(Square)

3/8”

(10 mm)

22 1/2” *

(572 mm)

33 5/8”

(854 mm)

NA

NA

NA

RGC/SGM466 with

PRV46

Figure 2

(Notched)

3/8”

(10 mm)

22 1/2” * 

(572 mm)

44 3/4”

(1137 mm)

43 1/2”

(1105 mm)

5/8”

(16 mm)

2 5/8” **

(67 mm)