PLANNING

GUIDE

DYRTP366, DYRTP486

Discovery

®

 

36” and 48” Wide

Slide-in Gas Rangetops

Document # PG04-007

Revised 10/17/14   Page 1/4

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required

Total Connected Load

120 Vac 60Hz, 15 Amp. (3 wire)

0.25 Amp @ 120 Vac, 60 Hz

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type

Manifold Pressure

Minimum Gas Supply 

Pressure

Natural Gas

5” Water Column

6” Water Column

Propane (LP)

10” Water Column

11” Water Column

* Maximum gas supply pressure for all models is 1/2 psi

IMPORTANT:

 Installation of a non-combustible material (up to the hood) or 

a backsplash is always recommended, and mandatory if the distance to the 

back wall from the rangetop is less than 2 1/2” (Figure 2). When installing 

a backguard, use only Dacor model numbers AEB3609 (DYRTP366) or 

AEB4809 (DYRTP486). Consult local codes and ordinances for acceptable 

non-combustible materials.

CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD

CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD

PRODUCT DIMENSIONS - SIDE VIEW

PRODUCT DIMENSIONS - ISO VIEW

A - Width

DYRTP366

35 7/8” (91.1 cm)

DYRTP486

47 7/8” (121.6 cm)

Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted

 WARNING

•  Observe all governing codes and ordinances during planning 

and installation. Contact your local building department for 

further information. 

•  This appliance must be installed in accordance with the 

accompanying installation instructions.

A

3 3/8”

 (8.6 cm)

7/16” 

(1.1 cm)

7 3/4”

 (19.7 cm)

Trim:

1/4”

 (6.4 mm)

thick

25 3/8” (64.5 cm)

1 1/4” (3.2 cm) cooking surface 

height (grate level) above 

countertop

3/4” NPT gas inlet, connects to regulator 

from bottom or rear of unit, end is recessed 

2” (5.1 cm) from chassis bottom

26 5/16” (66.8 cm)

27 5/16” (69.4 cm)

Power cord

40” long

Combustible

rear wall

Backguard mandatory if

gap from back of cooktop

to combustible wall is less

than 2 1/2”

Combustible

rear wall

2 1/2” (6.4 cm) min. to

combustible rear wall