PLANNING
GUIDE
DTI
xx
Modernist
®
30”
,
36”
Wide,
Electric Induction Cooktops
WARNING
• Follow local codes/ordinances during planning and installation. (Contact
the local building department for details.)
• The cooktop must be installed per its installation instructions. Dacor is
not responsible for product damage/failure due to faulty installation.
Doc #: PGH-
DTI
.01 Revised
19 Sept
2018 Page 1 of
3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
B
A
D
C
E
F
Cabinet
30” (mm)
36” (mm)
A
Frame Depth
21
1
/
4
” (540)
21
1
/
4
” (540)
B
Frame Width
30” (762)
36” (914)
C
Case Depth
19
1
/
2
” (494.6)
19” (481.6)
D
Case Width
28
3
/
8
” (720)
33
3
/
4
” (856.6)
E
Conduit Case Height
4” (101)
4” (101)
F
Case Height
3
1
/
8
” (80.5)
3
1
/
8
” (80.5)
IMPORTANT:
If installing a range hood or microwave hood combination
above the cooktop, follow the range hood or microwave
hood combination installation instructions for dimensions
and clearance above the cooktop surface.
G
F
A
C
E
E
D
B
Cooktop
Rear Wall
Countertop
Junction box
Minimum distance to
combustible side wall above
countertop (both sides)
DTI30M***** (30”)
DTI36M***** (36”)
A
28
1
/
2
” - 28
11
/
16
” (724 mm - 728 mm)
33
7
/
8
” - 34” (860 mm - 864 mm)
B
19
9
/
16
” - 19
5
/
8
” (497.4 mm - 499.4 mm)
19
1
/
8
” - 19
3
/
16
” (485.6 mm - 487.6 mm)
C
Min 1
1
/
8
” (28 mm). Between cutout and the wall behind the cooktop
D
Min 1
1
/
2
” (38 mm). From front edge of cutout and front edge of countertop
E
Min 1” (26 mm). Distance nearest left
-/
right
-
side combustible surface above cooktop.
F
Junction box or outlet 10” (254 mm) maximum from right-hand side of cabinet
G
Junction box or outlet 15” (381 mm) minimum from bottom of countertop