36
Deep Sleep
This function places the controller into ‘Deep Sleep’ when the input power supply fails. Internal process-
es, LEDs and external devices connected to the controller are switched off. Receiver response time is
slightly reduced. Battery standby time is increased by ±
1200%.
Solar Sleep
If enabled, this function allows the controller to enter into the selected sleep mode (Light, Medium or
Deep) while the input supply voltage is at a normal level. This is an advantage when the controller is
connected to a solar panel and the maximum amount of energy must be diverted to charging the battery.
USB SETTINGS
It is recommended that a full backup is made of the controller onto a USB Flash Drive or an Android
device connected to the USB input. This is particularly important when automating a complex so that all
settings can be restored easily should the operator require repairs or replacement.
Check the DACE website regularly for Tritek software updates. Save the updated software on to a USB
Flash Drive or Android device and update the Tritek controller. Remember to make a full backup of the
controller before loading the updated software.
Save Users
Saves all the Remote, Group and Time Management settings onto a USB Flash Drive or Android device.
Restore Users
Restores all the Remote, Group and Time management settings previously saved with the Save Users
function to the controller.
Any users added after the users were last saved onto the USB Flash Drive or Android device will be lost
with this operation.
Save Settings
This feature will save only the gate settings, it excludes the user settings i.e Remotes, Groups and Time
Management. A useful feature for a contractor who can cut down setup times by using a file of frequent-
ly applied gate settings
Restore Settings
Restores the gate settings to the controller previously saved using the Save Settings function.
The Tritek controller, by default, generates a Log File. This is a log of the last 1,024 events. These events
include user activity, type of operation, times, faults, power loss, alarm activation etc. This can assist with
fault finding and the tracking of users entering or exiting the premises.
Save Log file
Saves the Log File to a USB Flash Drive or Android device connected to the USB input.
Software Update
Upgrade or downgrade the current version of software to that saved on a USB Flash Drive or Android
device. The software version must be compatible with the hardware level.
Save Time Manager
Saves the Time Manager settings and times to a USB Flash Drive or Android device connected to the USB
input.
Restore Time Manager
This function will restore all the Time Manager settings and times saved using Save Time Manager.
Backup Controller
This function does a full controller backup and includes Remotes, Groups, Time Management and the
gate settings and times onto a USB Flash Drive or connected compatible Android phone.
Restore Controller
This function restores the controller from a full backup.