ENGLISH
22
5
DESCRIPTION OF DCONNECT BOX 2
1-
PLC connection
2-
Dab proprietary wireless connection
3-
Button for local Wi-Fi connection
4-
Service centre connection
5-
Wi-Fi connection
6-
Input
7-
Relay
8-
Modbus
9-
Modbus
Meaning of indicators
Indicator status
PLC (1)
Propriet. wireless (2)
Service centre (4)
Wi Fi (5)
Off
No connection
No connection
No connection
No connection
Blinking
Waiting to establish a
connection
Waiting to establish a
connection
-
Waiting to establish a connection
On
Connected
Connected
Connected
Connected
Table 3
Wi-Fi connection button
Used to create a direct connection between DCONNECT BOX 2 and a smartphone or tablet.
Holding the button down for 5 seconds, the LEDs (1) and (4) start blinking and the DCONNECT BOX 2 goes into access point mode. When the
device is in this status, it exhibits its own Wi-Fi network called DCONNECTBOX2-XXXXX to which you can connect directly through a
smartphone or tablet.
5.1
DCONNECT BOX 2 – ESYBOX DIVER connection
The pump connects to the DCONNECT BOX 2 via the Power Line Communication protocol, referred to as PLC. Thanks to this communication
channel, the user can monitor the pump status and actively interact through the app.
In order to communicate, ESYBOX DIVER and DCONNECT BOX 2 must be associated with each other and this operation is already done in
the factory. Once powered, the two units connect in a few minutes. During the device search phase, the PLC led (1) will blink regularly and once
correctly connected the led will remain on with a steady light.
The quality of the PLC connection can be influenced by many factors:
-
Power mains topology
-
Reactive loads present on the line
-
Connection length
-
Cable cross section
If there are communication problems, reduce the distance (and therefore the length of the electrical connection) between the two devices.
The two devices must be connected to the same single-phase power supply and must have a common phase and neutral.
5.2
DCONNECT BOX 2 – ESYBOX DIVER association
As already described, the two units in the same package are already associated in the factory, so this procedure should be used only in case of
replacement of one of the 2 units.