ENGLISH
79
or air bubbles that may impair operation. If the size of the pipeline enables transit of foreign bodies, a special filter may need to be
installed.
2.2.3
Connection of sensors
The ends for connecting the sensors are in the centre and are accessible by removing the screw of the connections cover, see Figure
3. The sensors must be connected to the relative inputs marked "Press" and "Flow"; see Figure 7.
Figure 9: Sensor connections
2.2.3.1
Connecting the pressure sensor
The inverter accepts two types of pressure sensor:
1.
Ratiometric 0 – 5V (Voltage sensor to be connected to connector press1)
2.
In current 4 - 20 mA (Current sensor to be connected to connector J5)
The pressure sensor is supplied with its own cable, and the cable and connection on the board varies according to the type of sensor
used. Both types of sensor can be supplied
2.2.3.1.1
Connecting a ratiometric sensor
One end of the cable must be connected to the sensor and the other end to the relative inverter pressure sensor input, marked "Press
1"; see Figure 7.
The cable has two different terminals with compulsory direction of insertion: connector for industrial applications (DIN 43650) on the
sensor side and 4-pole connector on the inverter side.
On multiple systems, the ratiometric pressure sensor (0-5V) can be connected to any inverter in the chain.
The use of ratiometric pressure sensors (0-5V) is strongly recommended to facilitate wiring. When using ratiometric
pressure sensors, there is no need for wiring to transfer pressure information readings between the various inverters.
The interconnection link cable deals with this operation
.
On systems with multiple pressure sensors, only ratiometric pressure sensors (0-5V) can be used (0-5V).
2.2.3.1.2
Connecting a 4 - 20 mA current sensor
Single inverter connection:
The selected 4-20mA current sensor has 2 wires, one brown (IN +) to connect to terminal 11 of J5 (V+), and one green (OUT -) to
connect to terminal 7 of J5 (A1C+). A jumper should also be wired in between terminal 9 and 10 of J5. The connections are shown in
Figure 8 and summarised in Table 5.
Summary of Contents for AD 1.0 AC
Page 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Page 74: ...ENGLISH 72 Figure 2 Fixture and minimum clearance for air circulation...
Page 135: ...FRAN AIS 133 Figure 2 Fixation et distance minimum pour la circulation de l air...
Page 196: ...DEUTSCH 194 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Page 257: ...ESPA OL 255 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Page 269: ...ESPA OL 267 Figura 13 Ejemplo de conexi n de las entradas...
Page 312: ...310 IEC 60634 1...
Page 313: ...311 1 6 1 1...
Page 317: ...315 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Page 318: ...316 2...
Page 319: ...317 2 2 3 3 15 2 2 1 1a 2a...
Page 320: ...318 4a 5b 1b 127 240 240 480 3 6 3b...
Page 324: ...322 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 332: ...330 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 333: ...331 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 12...
Page 335: ...333 3 2 2 13 SET 15 15 14 16...
Page 337: ...335 17 15 15 3 4 PW 6 6 16 GO SB...
Page 338: ...336 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Page 367: ...365 OC 10 6 OF 10 6 33 8 8 1 PMW 4 2 8 2 8 3 8 3 SET EE EEprom FLASH...
Page 379: ...NEDERLANDS 377 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Page 440: ...SVENSKA 438 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Page 501: ...T RK E 499 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Page 556: ...554 IEC 364 1 inverter...
Page 557: ...555 1 Inverter inverter inverter 6 inverter 1 1...
Page 561: ...559 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Page 562: ...560 2...
Page 563: ...561 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 1a 2a...
Page 564: ...562 4a 5b 1b V 127 240 240 480 mm 3 6 3b azione...
Page 568: ...566 2 2 2 inverter inverter GP GI 6 6 4 6 6 5 inverter 8 A B C D...
Page 576: ...574 3 14 oled 64 X 128 4 MODE SET 12 inverter 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 577: ...575 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5 2 2 12...
Page 581: ...579 17 15 15 3 4 Password inverter password password inverter password PW 6 6 16 GO SB FAULT...
Page 623: ...ROM N 621 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Page 684: ...POLSKI 682 Rys 2 Mocowanie oraz minimalna odleg o na potrzeby cyrkulacji powietrza...
Page 745: ...MAGYAR 743 2 bra R gz t s s minim lis t vols g a szell z leveg kering se rdek ben...
Page 800: ...798 IEC 364 1...
Page 801: ...799 1 3 1 1...
Page 805: ...803 1 2 1 1 1 1 2 5 2 1 2 1 2 C...
Page 806: ...804 2...
Page 807: ...805 2 2 3 3 15 2 2 1 1 2a...
Page 808: ...806 4a 5b 1b V 127 240 240 480 3 6 3b...
Page 812: ...810 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 817: ...815 V 36 36 12V A 3 3 3 3 2 13 9 11 8 13...
Page 819: ...817 3 14 64 X 128 4 MODE SET and 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 820: ...818 3 2 1 2 3 2 1 10 2 2 5 5 5 2 2 12...
Page 824: ...822 15 3 4 GO SB FAULT...
Page 825: ...823 4 4 1 8 4 2 4 2 1 16 18...
Page 862: ...ESKY 860 Obr zek 2 P ipevn n a minim ln vzd lenost kv li cirkulaci vzduchu...
Page 917: ...915 IEC 60634 1...
Page 918: ...916 1 6 1 1...
Page 922: ...920 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Page 923: ...921 2...
Page 924: ...922 2 2 3 3 15 2 2 1 1a 2a...
Page 925: ...923 4a 5b 1b 127 240 240 480 3 6 3b...
Page 929: ...927 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 931: ...929 10 4 20 6 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 4 20 7 OUT 8 10 11 IN...
Page 935: ...933 13 J5 I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 9...
Page 937: ...935 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 10 3 EEprom SET 6 SET MODE 3 1 11...
Page 938: ...936 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 11...
Page 940: ...938 3 2 2 13 SET 15 15 14 16...
Page 942: ...940 17 14 15 3 4 PW 6 6 16 GO SB FAULT...
Page 943: ...941 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Page 946: ...944 4 3 1 2 1 4 3 1 3 SET MODE LA RC MS FS SO AE O1 1 O2 2 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL...
Page 969: ...967 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...