background image

Box 125,

S-284 22 Perstorp

Sweden

Phone:

 +46 (0)435 77 95 00

Fax:

 +46 (0)435 77 95 29

E-mail: [email protected]

Automatic Control Panel, Type EP102

For electrically operated gates, barriers & doors

EP102-1 For control of one motor.      EP102-2 For control of two motors

User Manual

Version 1.03
Edition 1

Summary of Contents for EP102

Page 1: ...435 77 95 00 Fax 46 0 435 77 95 29 E mail daab daab port se Automatic Control Panel Type EP102 For electrically operated gates barriers doors EP102 1 For control of one motor EP102 2 For control of tw...

Page 2: ...sitions 13 Load sensor 13 Motor protection C44 C45 14 Limited running time 14 Latched deadman control 15 Functional check of load sensor safety buffer and photocell 15 Closure with deadman control in...

Page 3: ...ogramming pad are built onto the circuit board The basic control panel can be fitted with a range of accessories such as inductive vehicle detection loops radio control traffic lights and magnetic loc...

Page 4: ...open buffer inputs 4 safety buffers may be connected to the KS input terminals Resistance 2k with 1 tolerance and power resistance at least W Safety circuit Safety and test output 24V max 0 5A for con...

Page 5: ...ltages are compatible The largest motor size that can be connected is 0 55kW 3 phase See commissioning for how to check that the motor is running in the right direction Supply 3x400V with neutral Supp...

Page 6: ...ty circuit Safety buffer circuits must contain a 2 0K resistor to ensure that if the circuit fails it fails safe This control panel is designed for many applications therefore not all the input signal...

Page 7: ...rature G 2 17 Opening limit switch for motor 2 Breaks contact in fully open position GS2 18 Closing limit switch for motor 2 Breaks contact in fully closed position Control keys Name Term Function 24V...

Page 8: ...more than one DAAB type safety buffer is connected these should be connected in parallel and the number of buffers set in the control panel If more than one resistance switching buffer is used these c...

Page 9: ...tion it may be skipped during commissioning The following adjustments must be made to enable the panel to function Limit position Adjust limit switch Direction of rotation Check that the motor is runn...

Page 10: ...ction G 1 Lit indicates that motor 1 can open more off in open position GS1 Lit indicates that motor 1 can close more off in closed position G 2 Lit indicates that motor 2 can open more off in open po...

Page 11: ...t 2 Look at the channel list to check the number of the value you want to read 3 Step up or down with the or key to the correct channel number 4 Press the key the Value appears on the display Write va...

Page 12: ...buffer is actuated If the gate door is equipped with safety buffers for both opening and closing you can choose between several combinations for best personal security depending on type of gate or do...

Page 13: ...starting period This time can be adjusted and may vary depending on the weight and size of the gate If a value higher than 0 80 needs to be set there is presumably something wrong Contact DAAB for ad...

Page 14: ...s drawing too much current The built in motor protector measures the current of phase L1 The motor is protected if any phase disappears and the motor draws too much current If no current is obtained i...

Page 15: ...ror If the safety buffer or photocell is out of order the control panel reverts to deadman control for closing The gate can be closed by the deadman control if the close button is held down This funct...

Page 16: ...should be set in C53 NB If the gate should always close after a stop instruction 1 should be set in C53 to avoid the gate remaining open Setting automatic closure after stop has been actuated C52 C53...

Page 17: ...re use 5 Automatic closing turned off 6 Open gate automatic closing turned off Detailed explanations follows below Open stop close C62 1 If the door is moving and you give one signal to the input the...

Page 18: ...ning but not for closing Heat Lock You can have a heat lock by letting only one door open at a time A signal opens the first door which closes automatically When the first door is closed it opens the...

Page 19: ...r door can be opened independently Breaking the interlock during the summer Description The first door is opened When in the fully open position the stop button with lock is pressed The second door ca...

Page 20: ...with set up 2 can only be opened if the other door is open The door with set up 1 can only be opened if the other door is closed Door A can be opened when door B is open Door B can be opened when doo...

Page 21: ...2 00 99 Sec C13 Time motor 1 opened from closed position Used for limited opening 00 0 59 9 Sec C14 Number of openings Total no of openings C14 C15 000 999 times C15 Number of openings x1000 000 999...

Page 22: ...closure with FC SL Set time closure with FC SL 0 no closure with FC SL 0 00 9 59 min sec 0 00 C52 Time for blocking of automatic closure after actuation of stop key 0 20 9 59 min sec 5 00 C53 0 No aut...

Page 23: ...cking of load sensor at start 0 01 0 99 sec 0 60 C91 Time for motor protector 0 01 0 99 sec 0 30 C92 Time delay normal reversing Open and FC 0 6 1 0 sec 0 8 C93 Time delay rapid reversing Safety buffe...

Page 24: ...ode on or flashing Yes See displays No Load sensor Safety buffer Limit switches functioning Limit position display on No Motor thermocontact out of order Yes Limit switch out of order or circuit inter...

Page 25: ...setting Control panel registers that motor is on when it should be disengaged Someone has overridden the contactors E06 No current motor 1 E07 No current motor 2 Phase error Blown fuse Break in cable...