Da-Lite Ascender Electrol Instruction Book Download Page 3

3

 

CAUTION! Excessive continuous operation may cause 
overheating. If this happens, the motor will shut off until it 
cools to normal operating temperature. Standard duty cycle 
is 1 min. on / 15 min. off.

 

ATTENTION! Le fonctionnement continu et excessif peut 
provoquer une surchauffe et l'arrêt du moteur. Si cela se 
produit, les moteurs s'arrêteront jusqu'à qu'ils se soient 
refroidis à la température normale de fonctionnement. Le 
cycle de fonctionnement normal est de 1 min. en marche / 15 
min. à l'arrêt.

Screen Operation (continued)

Ascender Electrol® Installation

1.  For installations where the Ascender will be set on the floor, the 

box must be secured to floor in at least six places (recommended 
hardware is #12 x 2" L wood screws)(Figure 1). 

Screw Box Into Floor Stud

Floor

Floor

Box Frame Support

Figure 1

Figure 2

2.  For installations where the Ascender will be recessed into the 

floor, the box must be secured in at least six places 
(recommended hardware is #12 x 2" L wood screws)(Figure2).

1.  The Ascender screen can be operated by the included wall 

switch or by optional remote controls (IR or RF).

2.  To raise the screen, simply push and release the wall switch. The 

screen will stop at its preset position. If you push the switch a 
second time while it is rising, the screen will stop. By pushing the 
switch a third time the screen will retract and close.

3.  To lower the screen from the fully up position, press and release 

the wall switch and the screen will retract and close.

4.  Test the screen by running it up and down a few times. Be 

prepared to stop the screen if needed. 

Summary of Contents for Ascender Electrol

Page 1: ...INSTRUCTION BOOK FOR Ascender Electrol ...

Page 2: ...appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons Save These Instructions 1 The Ascender screen must be installed on a flat level surface 2 Remove the whi...

Page 3: ...ommended hardware is 12 x 2 L wood screws Figure 1 Screw Box Into Floor Stud Floor Floor Box Frame Support Figure 1 Figure 2 2 For installations where the Ascender will be recessed into the floor the box must be secured in at least six places recommended hardware is 12 x 2 L wood screws Figure2 1 The Ascender screen can be operated by the included wall switch or by optional remote controls IRor RF...

Page 4: ...en is down will be an up command 3 A momentary closure when the screen is fully extended will be a down command 4 A momentary closure while the screen is in motion will be a stop command CAUTION Never apply voltage to the wall switch lead or the LVC will be damaged ATTENTION N appliquez jamais une tension aux fils du commutateur mural sinon le tableau de contrôle basse tension sera endommagé 120V ...

Page 5: ...te Common Single Pull Single Throw Momentary Contact Switch Up Stop Down Off Up Stop Down Off Black White Common Black Not Used Figure 3b Power Input 240 VAC 50 HZ Green Yellow Ground Single Pull Single Throw Momentary Contact Switch Door Microswitch Motor 240V Wiring Diagram Brown Up Black Down Blue Common Blue Common Brown Hot Green Yellow Ground Not Used Optional IR Or RF Connection White Commo...

Page 6: ...eat until the desired position is set To Adjust The Down Position 1 Raise the screen about one foot and stop Turn the red limit adjuster counterclockwise one quarter turn to increase the down travel CAUTION Do not adjust the screen down too far This will strain the motor and screen The lid of the box should just close when the motor stops ATTENTION Ne déroulez pas trop l écran Cela forcera le mote...

Page 7: ...wer to operating switch or junction Check above Tighten all loose wire connections Correct any improper connections Up Position Check for power across black and white leads Power at junction box Thermal overload tripped Let motor cool down for 15 minutes Try again Broken wire in the up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace ...

Page 8: ...o Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNES...