D-Link xStack DES-3528P Series Hardware Installation Manual Download Page 1

 

®  

 

 

 

  

  

 

 

  

 

Hardware Installation Guide

 

Product Model:

 

xStack

®

 

DES-3528/DES-3552 Series

 

Layer 2 Managed Stackable Fast Ethernet Switch 

Release 2.0

 

Summary of Contents for xStack DES-3528P Series

Page 1: ... Hardware Installation Guide Product Model xStack DES 3528 DES 3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Release 2 0 ...

Page 2: ...mission of D Link Corporation is strictly forbidden Trademarks used in this text D Link and the D LINK logo are trademarks of D Link Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products D Link Corporation disclaims any propriet...

Page 3: ...ic environment this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produkt der Klasse A Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Massnahmen zu ergreifen Precaución Este es un producto de Clase A En un entorno doméstico puede causar interferen...

Page 4: ...t Combo Ports 10 Installation 12 Package Contents 12 Before You Connect to the Network 12 Installing the Switch without the Rack 13 Installing the Switch in a Rack 13 Mounting the Switch in a Standard 19 Rack 14 Power On AC Power 14 Power Failure AC Power 14 Connecting DC Power to the DES 3528DC 15 Connecting the Switch 16 Switch to End Node 16 Switch to Hub or Switch 16 Connecting To Network Back...

Page 5: ...r 2 Stackable Fast Ethernet Managed Switch User Manual iv Introduction 24 Login to Web Manager 24 Web based User Interface 25 Web Pages 26 Technical Specifications 27 Cable Lengths 34 Glossary 35 Warranties and Tech Support Information 38 ...

Page 6: ...am names and commands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prompts that must be typed exactly as printed in the manual Initial capital letter Indicates a window name Names of keys on the keyboard have initial capitals For example Click Enter Italics Indicates a window name or a field Also can indicate a variables or parameter that is replace...

Page 7: ...d never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Use the product only with approved equipment Allow the product to cool before removing covers ...

Page 8: ...es of power disconnect power from the system by unplugging all power cables from the power supplies Move products with care ensure that all casters and or stabilizers are firmly connected to the system Avoid sudden stops and uneven surfaces General Precautions for Rack Mountable Products Observe the following precautions for rack stability and safety Also refer to the rack installation documentati...

Page 9: ... if the safety ground cable is omitted or disconnected Protecting Against Electrostatic Discharge Static electricity can harm delicate components inside your system To prevent static damage discharge static electricity from your body before you touch any of the electronic components such as the microprocessor You can do so by periodically touching an unpainted metal surface on the chassis You can ...

Page 10: ...rnet utilizing the same packet structure format and support for full duplex flow control and management objects but with a tenfold increase in theoretical throughput over 100Mbps Fast Ethernet and a one hundred fold increase over 10Mbps Ethernet Since it is compatible with all 10Mbps and 100Mbps Ethernet environments Gigabit Ethernet provides a straightforward upgrade without wasting a company s e...

Page 11: ... Port Utilization support System Log Support Support port based enable and disable Address table Supports up to 16K MAC addresses per device Supports a packet buffer of up to 1 Mbyte Supports Port based VLAN Groups Port Trunking with flexible load distribution and fail over function IGMP Snooping support SNMP support Secure Sockets Layer SSL and Secure Shell SSH support Port Mirroring support MIB ...

Page 12: ...ex IEEE 802 3af compliant DES 3528P DES 3552P only Auto MDI X MDI II cross over support SFP Transceivers Supported DEM 310GT 1000BASE LX DEM 311GT 1000BASE SX DEM 314GT 1000BASE LHX DEM 315GT 1000BASE ZX DEM 312GT2 1000BASE SX DEM 210 Single Mode 100BASE FX DEM 211 Multi Mode 100BASE FX WDM Transceiver Supported DEM 330T TX 1550 RX 1310nm up to 10km Single Mode DEM 330R TX 1310 RX 1550nm up to 10k...

Page 13: ...nt Panel View of the DES 3528 switch DES 3528P Twenty four 10 100Mbps BASE T ports Two Combo 1000BASE T SFP ports located to the right Two 1000BASE T ports located to the rear One female DCE RS 232 DB 9 console port One PoE Select Button LEDs for Power Console RPS MS Link PoE Link Act Speed for each port Figure 1 2 Front Panel View of the DES 3528P switch DES 3528DC Twenty four 10 100Mbps BASE T p...

Page 14: ...emale DCE RS 232 DB 9 console port One PoE Select Button LEDs for Power Console RPS MS Link PoE Link Act Speed for each port Figure 1 5 Front Panel View of the DES 3552P switch LED Indicators The Switch supports LED indicators for Power Console RPS Master on DES 3528P and DES 3552P this LED is for MS and Port LEDs The following shows the LED indicators for the DES 3528 DES 3552 switch series along...

Page 15: ...xStack DES 3528 DES 3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual 6 Figure 1 9 LED Indicators on DES 3528P switch Figure 1 10 LED Indicators on DES 3552P switch ...

Page 16: ...ts work bi functionally The box ID and H indicate the primary Master and the display on other switches will be shown in turn That is boxID H boxID H Mode Select Button DES 3528P and DES 3552P only Link Act Speed Green Solid Light Link Act Speed Mode PoE Green Solid Light PoE Mode LED Per 10 100 Mbps Port Link Act Speed Green Amber Solid Green When there is a secure 100Mbps Fast Ethernet connection...

Page 17: ...10 100Mbps Fast Ethernet connection or link at any of the ports Blinking Amber When there is reception or transmission i e Activity Act of data occurring at a 10 100Mbps Fast Ethernet connected port Light off No link LED per SFP Port Link Act Speed Green Amber Solid Green When there is a secure 1000Mbps connection or link at the ports Blinking Green When there is reception or transmission i e Acti...

Page 18: ...e 1 14 Rear panel view of the DES 3552P The AC power connector is a standard three pronged connector that supports the power cord Plug in the female connector of the provided power cord into this socket and the male side of the cord into a power outlet The Switch automatically adjusts its power setting to any supply voltage in the range from 100 240 VAC at 50 60 Hz The rear panel also includes an ...

Page 19: ...DES 3552 DES 3528P The right hand side panel of the DES 3552P Switch contains three system fans and ventilation along the entire right side The left hand panel includes a heat vent The system fans are used to dissipate heat Do not block these openings on either side of the Switch Leave at least 6 inches of space at the rear and sides of the Switch for proper ventilation Be reminded that without pr...

Page 20: ...28 DES 3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual 11 Figure 1 19 Inserting the SFP modules into the DES 3528 DES 3528P DES 3528DC DES 3552 DES 3552P Figure 1 20 Installing the SFP Module ...

Page 21: ...ffect its performance Please follow these guidelines for setting up the Switch Install the Switch on a sturdy level surface that can support at least 6 6 lbs 3 kg of weight for DES 3528 DES 3528DC at least 13 2 lbs 6 kg of weight for DES 3552 DES 3528P at least 15 4 lbs 7 kg of weight for DES 3552P Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the...

Page 22: ... device Allow enough ventilation space between the Switch and any other objects in the vicinity Figure 2 1 Preparing the Switch for installation on a desktop or shelf Installing the Switch in a Rack The Switch can be mounted in a standard 19 rack Use the following diagrams to guide you Figure 2 2 Fasten mounting brackets to the Switch Fasten the mounting brackets to the Switch using the screws pro...

Page 23: ...n one component out of the rack on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip over and may result in injury Figure 2 3 Installing the Switch in a rack Power On AC Power Plug one end of the AC power cord into the power connector of the Switch and the other end into the local power source outlet After the Switch is powered on the LED i...

Page 24: ...DES 3528DC to the DC power source Figure 2 4 Power connections attached to contacts after assembly 1 Firmly attach the DC power to the negative and positive contacts on the wiring assembly The negative pole connects to the 48V contact The positive pole connects to the 48V Return contact An earth ground may be connected to the center contact post 2 Tighten the contact screws to secure the connectio...

Page 25: ...wisted pair Category 3 4 or 5 UTP STP cable The end node should be connected to any of the ports of the Switch Figure 3 1 The Switch connected to an end node The Link Act LEDs for each UTP port will light green or amber when the link is valid A blinking LED indicates packet activity on that port Switch to Hub or Switch These connections can be accomplished in a number of ways using a normal cable ...

Page 26: ...combo ports are ideal for linking to a network backbone or server The copper ports operate at a speed of 1000 100 or 10Mbps in full or half duplex mode The fiber optic ports can operate at 100Mbps or 1000Mbps in full duplex mode Connections to the Gigabit Ethernet ports are made using fiber optic cable or Category 5E copper cable depending on the type of port A valid connection is indicated when t...

Page 27: ...responds to requests with MIB objects stored in the database The SNMP agent updates the MIB objects to generate statistics and counters Connecting the Console Port RS 232 DCE The Switch provides an RS 232 serial port that enables a connection to a computer or terminal for monitoring and configuring the Switch This port is a female DB 9 connector implemented as a data communications equipment DCE c...

Page 28: ...ram 14 Make sure the terminal or PC you are using to make this connection is configured to match these settings If you are having problems making this connection on a PC make sure the emulation is set to VT 100 You will be able to set the emulation by clicking on the File menu in you HyperTerminal window clicking on Properties in the drop down menu and then clicking the Settings tab This is where ...

Page 29: ...Username PassWord DES 3528 5 Figure 4 2 Command Prompt NOTE The first user automatically gets Administrator level privileges It is recommended to create at least one Admin level user account for the Switch Password Protection The Switch does not have a default user name and password One of the first tasks when settings up the Switch is to create user accounts Once logged in using a predefined admi...

Page 30: ...anagement Information Base MIB which provides a standard presentation of the information controlled by the on board SNMP agent SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network The Switch supports SNMP versions 1 2c and 3 You can specify which version of SNMP you want to use to monitor and control the Switch The three versions ...

Page 31: ...ement software In addition to the standard MIB II the Switch also supports its own proprietary enterprise MIB as an extended Management Information Base Specifying the MIB Object Identifier may also retrieve the proprietary MIB MIB values can be either read only or read write IP Address Assignment Each Switch must be assigned its own IP Address which is used for communication with an SNMP network ...

Page 32: ...the y s represent the corresponding subnet mask Alternatively you can enter config ipif System ipaddress xxx xxx xxx xxx z Where the x s represent the IP address to be assigned to the IP interface named System and the z represents the corresponding number of subnets in CIDR notation The IP interface named System on the Switch can be assigned an IP address and subnet mask and then be used to connec...

Page 33: ...d Telnet are different ways to access the same internal switching software and configure it Thus all settings encountered in web based management are the same as those found in the console program Login to Web Manager To begin managing the Switch simply run the browser you have installed on your computer and point it to the IP address you have defined for the device The URL in the address bar shou...

Page 34: ... be opened to display the hyper linked window buttons and subfolders contained within them Click the D Link logo to go to the D Link website Area 2 Presents a graphical near real time image of the front panel of the Switch This area displays the Switch s ports and expansion modules showing port activity duplex mode or flow control depending on the specified mode Various areas of the graphic can be...

Page 35: ...Spanning Tree Forwarding Filtering LLDP CFM and Ethernet OAM L3 Features A discussion of the Layer 3 features on the Switch including Ipv4 Interface Settings Ipv4 Default Route Settings Gratuitous ARP ARP Spoofing Prevention Settings DNS Relay DHCP Server and Policy Route Settings QoS Features information on Switch QoS functions including HOL Blocking Prevention Bandwidth Control Traffic Control 8...

Page 36: ...HX DEM 315GT 1000BASE ZX DEM 312GT2 1000BASE SX DEM 210 Single Mode 100BASE FX DEM 211 Multi Mode 100BASE FX WDM Transceivers Supported DEM 330T TX 1550 RX 1310nm up to 10km Single Mode DEM 330R TX 1310 RX 1550nm up to 10km Single Mode DEM 331T TX 1550 RX 1310nm up to 40km Single Mode DEM 331R TX 1310 RX 1550nm up to 40km Single Mode Standards IEEE802 3 Data Transfer Rates Ethernet Fast Ethernet G...

Page 37: ...C Power Input 36 75 V DC 0 6A Max Output 12V 1 2A Max Internal universal power supply DES 3528 DES 3552 Provides one connector on the rear panel to install an optional external RPS DPS 200 to enhance the reliability When the internal power fails the optional external RPS will take over all the power immediately and automatically DES 3528P DES 3552P Provides one connector on the rear panel to insta...

Page 38: ... C Humidity Operation Relative Humidity 5 95 non condensing Storage Relative Humidity 5 95 non condensing Dimensions DES 3528 DES 3528DC 441 W x 210 D x 44 H mm DES 3552 DES 3528P 441 W x 310 D x 44 H mm DES 3552P 441 W x 370 D x 44 H mm Weight DES 3528 2 51kg 5 53lbs DES 3528DC 2 52kg 5 55lbs DES 3552 4 09kg 9 01lbs DES 3528P 5 42kg 11 94lbs DES 3552P 6 52kg 14 37lbs EMI CE Class A FCC Class A C ...

Page 39: ...smission Method Store and forward Packet Buffer 1 MB per device Packet Filtering Forward Rate 14 881 pps 10M port 148 810 pps 100M port 1 488 100 pps 1 Gbps port Port Functions Feature Detailed Description Console Port DCE RS 232 DB 9 for out of band configuration of the software features 10 100BaseT ports Compliant to following standards IEEE 802 3 compliance IEEE 802 3u compliance Support Half F...

Page 40: ...550nm up to 10km Single Mode DEM 331T TX 1550 RX 1310nm up to 40km Single Mode DEM 331R TX 1310 RX 1550nm up to 40km Single Mode Compliant to following standards IEEE 802 3z compliance IEEE 802 3u compliance 1000BASE T ports 1000BASE T ports compliant to following standards IEEE 802 3 compliance IEEE 802 3u compliance IEEE 802 3ab compliance Support Full Duplex operations IEEE 802 3x Flow Control ...

Page 41: ...ow Class Usage Max power used by PD 0 Default 0 44 to 12 95W 1 Optional 0 44 to 3 84W 2 Optional 3 84 to 6 49W 3 Optional 6 49 to 12 95W 4 Reserved 12 95W to 30W 6 PSE should be provide the power following the classification below Class Usage Max power used by PD 0 Default 15 4W 1 Optional 4 0W 2 Optional 7 0W 3 Optional 15 4W 4 Reserved 15 4W 30W 7 DES 3528P 52P follow the standard PSE pin out st...

Page 42: ...Receive signal 2 Receive Negation Receive signal 3 Transmit Positive Transmit signal 4 5 6 Transmit Negation Transmit signal 7 8 FE Port PSE Pinout Assignment for Power Pairs alternative A MDI X PIN Signal Description 1 Negative Vport Negative power signal 2 Negative Vport Negative power signal 3 Positive Vport Positive power signal 4 5 6 Positive Vport Positive power signal 7 8 ...

Page 43: ...able lengths Standard Media Type Maximum Distance SFP 1000BASE LX Single mode fiber module 1000BASE SX Multi mode fiber module 1000BASE LHX Single mode fiber module 1000BASE ZX Single mode fiber module 10km 550m 40km 80km 1000BASE T Category 5e UTP Cable 100m 100BASE TX Category 5 and Category 5e UTP Cable 100 Mbps 100m 10BASE T Category 3 4 5 and 5e UTP Cable 10 Mbps 100m ...

Page 44: ...nts BOOTP The BOOTP protocol allows you to automatically map an IP address to a given MAC address each time a device is started In addition the protocol can assign the subnet mask and default gateway to a device bridge A device that interconnects local or remote networks no matter what higher level protocols are involved Bridges form a single logical network centralizing network administration bro...

Page 45: ... data transmission should the other fail See also main port and standby port RJ 45 Standard 8 wire connectors for IEEE 802 3 10BASE T networks RMON Remote Monitoring A subset of SNMP MIB II that allows monitoring and management capabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a backup source of power when connected to the Switch...

Page 46: ... device to send a datagram to an application program on another device VLAN Virtual LAN A group of location and topology independent devices that communicate as if they are on a common physical LAN VLT Virtual LAN Trunk A Switch to Switch link which carries traffic for all the VLANs on each Switch VT100 A type of terminal that uses ASCII characters VT100 screens have a text based appearance ...

Page 47: ...ation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the pr...

Page 48: ...ms Inc Other trademarks or registered trademarks are the property of their respective owners Copyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United ...

Page 49: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 50: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Page 51: ... uk ftp ftp dlink co uk Technische Unterstützung Deutschland Web http www dlink de E Mail support dlink de Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Österreich Web http www dlink at E Mail support dlink at Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Schweiz Web http www dlink ch E Mail support dlink ch Telefon 41 0 848 331100 0 08 CHF pro Minute ...

Page 52: ...0 15ppm anytime Tech Support for customers within Belgium 070 66 06 40 www dlink be 0 175ppm peak 0 0875ppm off peak Tech Support for customers within Luxemburg 32 70 66 06 40 www dlink be Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http www dlink es Supporto tecnico Supporto Tecnico dal lunedì al venerdì dalle ore 9 00 al...

Page 53: ... PO PÁ od 09 00 do 17 00 Pevná linka 1 78 CZK min mobil 5 40 CZK min Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http www dlink hu Teknisk Support D Link Teknisk telefon Support 820 00 755 Hverdager 08 00 20 00 D Link Teknisk Support over Internett http www dlink no Teknisk Support D Link teknisk support over telef...

Page 54: ...εφαλληνίας 64 11251 Αθήνα Τηλ 210 86 11 114 Δευτέρα Παρασκευή 09 00 17 00 Φαξ 210 8611114 http www dlink gr support Assistência Técnica Assistência Técnica da D Link na Internet http www dlink pt e mail soporte dlink es Teknisk Support D Link Teknisk Support via telefon 0900 100 77 00 Vardagar 08 00 20 00 D Link Teknisk Support via Internet http www dlink se ...

Page 55: ...k biz hr Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu www dlink biz sl Suport tehnica Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu www dlink ro ...

Page 56: ...b www dlink co in E Mail helpdesk dlink co in Indonesia Malaysia Singapore and Thailand Tel 62 21 5731610 Indonesia Tel 1800 882 880 Malaysia Tel 65 6501 4200 Singapore Tel 66 2 719 8978 9 Thailand 24 7 for English Support only Web http www dlink com sg support E mail support dlink com sg Korea Tel 82 2 2028 1815 Monday to Friday 9 00am to 6 00pm Web http www d link co kr E mail arthur d link co k...

Page 57: ...92 21 4548158 92 21 4548310 Monday to Friday 10 00am to 6 00pm Web http support dlink me com E mail zkashif dlink me com South Africa and Sub Sahara Region Tel 27 12 665 2165 08600 DLINK for South Africa only Monday to Friday 8 30am to 9 00pm South Africa Time Web http www d link co za E mail support d link co za Turkey Tel 90 212 2895659 Monday to Friday 9 00am to 6 00pm Web http www dlink com tr...

Page 58: ...ink D Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока Клиенты могут обратиться в группу технической поддержки D Link по телефону или через Интернет Техническая поддержка D Link 7 495 744 00 99 Техническая поддержка через Интернет http www dlink ru e mail support dlink ru ...

Page 59: ...ombia 01800 9525465 Lunes a Viernes 06 00am a 19 00pm Costa Rica 0800 0521478 Lunes a Viernes 05 00am a 18 00pm Ecuador 1800 035465 Lunes a Viernes 06 00am a 19 00pm El Salvador 800 6335 Lunes a Viernes 05 00am a 18 00pm Guatemala 1800 8350255 Lunes a Viernes 05 00am a 18 00pm México 01800 1233201 Lunes a Viernes 06 00am a 19 00pm Panamá 011 008000525465 Lunes a Viernes 05 00am a 18 00pm Perú 0800...

Page 60: ...ra clientes no Brasil durante o período de vigência da garantia deste produto Suporte Técnico para clientes no Brasil Website para suporte www dlink com br suporte e mail suporte dlink com br Telefones para contato Clientes de São Paulo 2755 6950 Clientes das demais regiões 0800 70 24 104 Segunda à Sexta feira das 9 00h às 21 00h Sábado das 9 00h às 15 00h ...

Page 61: ...方式與D Link台灣 地區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Page 62: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Page 63: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただくと ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Page 64: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 8008296688 028 66052968 技术支持中心传真 028 85176948 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 办公时间 周一到周五 早09 00到晚18 00 ...

Page 65: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 66: ......

Reviews: