Software User Manual
D-Link Unified Access System
12/10/09
Document
34CSFP6XXUWS-SWUM100-D7
Serial Port
Page 65
S
ERIAL
P
ORT
The Serial Port Configuration page allows you to change the switch’s serial port settings. In order for a terminal or terminal
emulator to communicate with the switch, the serial port settings on both devices must be the same. Some settings on the
switch cannot be changed.
To view or configure the serial port settings on the switch, click
LAN > Administration > Serial Port
in the navigation tree.
Figure 15: Serial Port
•
If you change any data, click
Submit
to apply the changes to the system. If you want the switch to retain the new values
across a power cycle, you must perform a save.
Table 9: Serial Port Fields
Field
Description
Serial Port Login Timeout
(minutes)
Indicates how many minutes of inactivity should occur on a serial port connection
before the switch closes the connection. Enter a number between 0 and 160. The
factory default is 5. Entering 0 disables the timeout.
Baud Rate (bps)
Select the default baud rate for the serial port connection from the menu. The factory
default is 115200.
Character Size (bits)
The number of bits in a character. This is always 8.
Flow Control
Whether hardware flow control is enabled or disabled. It is always disabled.
Stop Bits
The number of stop bits per character. Its is always 1.
Parity
The parity method used on the serial port. It is always None.