User Accounts
D-Link
Unified Wired and Wireless Access System
Oct. 2015
Page 79
D-Link UWS User Manual
Table 13: User Accounts Fields
Field
Description
User
From the
User
menu, select an existing user to configure, or select
Create
to
create a new user account. The system can have a maximum of five 'Read
Only' accounts and one Read/Write account.
User Name
Enter the name to give to the account. User names are up to eight characters
in length and are not case sensitive. Valid characters include all the
alphanumeric characters as well as the dash ('-') and underscore ('_')
characters.User name
default
is not valid.
Note:
You can change the Read/Write user name from “admin” to something
else, but when you click Submit, you must re-authenticate with the new
username.
Password
Enter the optional new or changed password for the account. It will not
display as it is typed, and only asterisks (*) will show on the screen. Passwords
are up to eight alpha numeric characters in length and are case sensitive.
Confirm Password
Enter the password again, to confirm that you entered it correctly. This field
will not display, but will show asterisks (*)
Access Mode
Indicates the user's access mode. The admin account always has Read/Write
access, and all other accounts have Read Only access.
Lockout Status
Indicates whether the user is currently locked out. A user is locked out after a
certain number of failed login attempts.
Password Override-
Complexity-Check
This selector lists the two options for Override-Complexity-Check: Enable and
Disable. The default value is Disable. Enable is to override the password
strength check feature, Disable is to perform the password strength check
feature.
Password Expiration Date
Indicates the date when this user’s current password will expire. This is
determined by the date the password was created and the number of days
specified in the aging Password Aging setting on the Password Management
page.
SNMPv3 User Configuration
SNMPv3 Access Mode
Indicates the SNMPv3 access privileges for the user account. The admin
account always has 'Read/Write' access, and all other accounts have 'Read
Only' access.
Authentication Protocol
Specify the SNMPv3 Authentication Protocol setting for the selected user
account. The valid Authentication Protocols are None, MD5 or SHA. If you
select None, the user will be unable to access the SNMP data from an SNMP
browser. If you select MD5 or SHA, the user login password will be used as the
SNMPv3 authentication password, and you must therefore specify a
password, and it must be eight characters long.
Encryption Protocol
Specify the SNMPv3 Encryption Protocol setting for the selected user account.
The valid Encryption Protocols are None or DES. If you select the DES Protocol
you must enter a key in the Encryption Key field. If None is specified for the
Protocol, the Encryption Key is ignored.
Configure Encryption
The check box must be checked in order to change the Encryption Protocol
and Encryption Key.
Summary of Contents for DWL-8600AP
Page 754: ......