background image

 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Rev. 01 (JUN. 2002) 

 

1907MCB10016000 

 

 
 
                                     
                                   

RECYCLABLE 

SNMP Module for 

Chassis-Based Media Converter  

Manual 

 

DMC-1002 

Summary of Contents for DMC-1002

Page 1: ...Rev 01 JUN 2002 1907MCB10016000 RECYCLABLE SNMP Module for Chassis Based Media Converter Manual DMC 1002...

Page 2: ...R CHASSIS SYSTEM 3 INSTALLING THE MANAGEMENT MODULE 3 CONFIGURE THROUGH WEB BROWSER 4 CONFIGURATION VIA SERIAL PORT 4 SUPPORT SNMP MANAGEMENT 5 LED INDICATORS 5 MANAGEMENT SETTING THROUGH WEB BROWSER...

Page 3: ...nverter type Slot number occupied 2 Status Indication of Chassis Redundant Power status Power Fail status Fan Fail status 3 Status Indication of Modules Unit Power Link Activity Transmit Receive LED I...

Page 4: ...etwork administrator or manager with an understanding of network operations The Media Converter Chassis system The chassis s first slot is for the management module as illustration on figure 1 Figure...

Page 5: ...rminal emulator attached to the RS232 serial port on the Switch too NOTE 1 The serial port cable is attached directly with the device 2 It needs to upgrade the Terminal Emulator due to key malfunction...

Page 6: ...shows the LED indicators for the Switch along with an explanation of each indicator DMC 1000i Power On Lights green when the power is inserted Power Fail Lights Amber when the power is inserted and it...

Page 7: ...BROWSER 1 Main Menu Figure 1 Main Menu 1 1 System Function There are four items in System Function menu Software Reboot Factory Reset Image Update and Configuration Update Figure 2 1 2 Configuration T...

Page 8: ...1002 and all system all smart device installed in chassis back to the default setting in case of the messy setting 1 1 4 Image Update The section is to set the TFTP Server IP Address first and the def...

Page 9: ...8 While the file is uploading to the system it will appear a warning sign Figure 3 2 Figure 3 1 Figure 3 2...

Page 10: ...laining how to upload and download the configure setting of the module The Configuration Upload is to restore a setting file to the management module The Configuration Download is to backup the settin...

Page 11: ...the admit password Confirm Password to confirm the setting of admit password System Name to authorize the device system name Location to show the device where it is located Refresh time to set the ref...

Page 12: ...m device need to press the save button to save the setting 1 2 3 SNMP Configuration Figure 7 Get Community Name to get the device community name default public Set Community Name to set the device com...

Page 13: ...evice and workstation are different default enable Power Fail Trap to set the Power Fail Trap default enable Fan Fail Trap to set the fan fail trap default enable MC Plug in Trap to set the trap of th...

Page 14: ...AL EMULATOR 2 Main Menu Figure 8 2 1 System Function There are three items in System Function menu Software Reboot Factory Reset Image Update Figure 9 Figure 9 2 1 1 Software Reboot To reboot for the...

Page 15: ...to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server Figure 10 Note The content of the...

Page 16: ...n noted the version of the hardware BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware Change Password the changing of the admit password Confirm Password...

Page 17: ...ress for the device the default IP is 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default GW to set the gateway address the default is 192 168 1 254 NOTE After configur...

Page 18: ...es and X stands for No Plug in indicates if Power 1 or 2 was plugged in or not Power Fail indicates if the Power 1 or 2 is fail or not Fan Fail indicates if the Fan 1 or 2 is fail or not 2 2 4 Media C...

Page 19: ...Status Figure 15 2 To control the linkage of each media converter 2 3 SNMP Configuration Figure 16 Get Community Name to get the device community name default public Set Community Name to set the dev...

Page 20: ...set the trap of the Media Converter module if it is plugged in default enable MC Pullout Trap to set the trap of the Media Converter module if it is pulled out default enable Appendix A When forgot th...

Page 21: ...3 4 5 up to 100 m 328 ft 100BASE TX 2 pair UTP Cat 5 up to 100 m 328 ft LED Indicator Power 1 and 2 Power Fail 1 and 2 Fan Fail 1 and 2 MGM Green CPU working Blinking Amber CPU Fail Console Blinking...