DMC-1001
Redundant Power Supply
User’s Guide
Rev. 01 (JAN. 2002)
Printed In Taiwan
RECYCLABLE
Page 1: ...DMC 1001 Redundant Power Supply User s Guide Rev 01 JAN 2002 Printed In Taiwan RECYCLABLE ...
Page 2: ...e 100 of the load without any loss Similarly if one power supply is removed from servicing it can be switched off and removed while the chassis continues functioning Product Features 9 Efficiency The efficiency is higher than 70 by measured at nominal line and rated load 9 Protection Over voltage protection short circuit protection 9 Power sharing and redundancy 9 Fan failure Signal The power supp...
Page 3: ...the Power Supply z To remove a power supply out the chassis you have to loose the hand screw counter clockwise and pull out the power supply from the chassis z To install a power supply to the chassis you have to fasten the hand screw clockwise and slide in the power supply to the chassis You c an slide in and out the power supply from the bay fasten or loose the hand sc rew c loc kwise or c ounte...
Page 4: ...mption 150 watts max Dimension 185 x 160 x 85 mm Temperature Operating 0 40 C Storage 10 50 C Humidity Operating 10 90 Storage 5 90 Overload Protection All outputs protected from short circuit condition automatic recovery Emissions FCC Class A CE Mark Class A VCCI Class A Safty Standard UL 1950CSA CSA 22 2 No 234 ...