DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
221
The steps required to use the SSH protocol for secure communication between a remote PC (the SSH client) and the
Switch (the SSH server) are as follows:
•
Create a user account with admin-level access using the User Accounts window. This is identical to creating
any other admin-level User Account on the Switch, including specifying a password. This password is used to
logon to the Switch, once a secure communication path has been established using the SSH protocol.
•
Configure the User Account to use a specified authorization method to identify users that are allowed to
establish SSH connections with the Switch using the SSH User Authentication Mode window. There are three
choices as to the method SSH will use to authorize the user, which are Host Based, Password, and Public Key.
•
Configure the encryption algorithm that SSH will use to encrypt and decrypt messages sent between the SSH
client and the SSH server, using the SSH Authentication Method and Algorithm Settings window.
•
Finally, enable SSH on the Switch using the SSH Configuration window.
After completing the preceding steps, a SSH Client on a remote PC can be configured to manage the Switch using a
secure, in band connection.
SSH Global Settings
This window is used to display and configure the global SSH settings.
To view the following window, click
Security > SSH > SSH Global Settings
, as shown below:
Figure 9-67 SSH Global Settings Window
The fields that can be configured are described below:
Parameter
Description
IP SSH Server State
Select to enable or disable the global SSH server state.
IP SSH Service Port
Enter the SSH service port number used here. This value must be between 1 and
65535. By default, this number is 22.
Authentication Timeout
Enter the authentication timeout value here. This value must be between 30 and
600 seconds. By default, this value is 120 seconds.
Authentication Retries
Enter the authentication retries value here. This value must be between 1 and 32.
By default, this value is 3.
Click the
Apply
button to accept the changes made.