background image

HQ series

User's Manual

Antes  de  utilizar  el  equipo,  lea  la  sección 
“Precauciones  de  seguridad”  de  este  manual. 
Conserve este manual para futuras consultas.

Before  operating  the  device,  please  read  the 
“Safety  precautions”  section  of  this  manual. 
Retain this manual for future reference.

Summary of Contents for HQ series

Page 1: ...utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ...

Page 2: ...AWINGS 3 4 5 11 10 12 15 16 18 19 INSTALLATION SPECIFICATIONS ACCESSORIES ANNEX Table for cable selection CONFIGURATIONS SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY 4x HQ 112 xx horizontal array 4x HQ 112 95 2x HQ 218 horizontal array 6x HQ 112 43 2x HQ 218 vertical array ...

Page 3: ...cal and electronic equipment El cableado exterior conectado al equipo requiere de su instalación por una persona instruida o el uso de cables flexibles ya preparados The outer wiring connected to the device requires installation by an instructed person or the use of a flexible cable already prepared El colgado del equipo sólo debe realizarse utilizando los herrajes de colgado recomendados y por pe...

Page 4: ...ntía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra GARANTÍA All D A S products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised ...

Page 5: ...ty Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emission l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity Cumple con los objetivos esenciales de las Directivas Abide by essential object...

Page 6: ...iver with titanium diaphragm Rotatable 60º x 40º horn design Trapezoid geometry enclosure Finish CX covered exposure and DX direct exposure 20 built in rigging points The HQ 112 64 is a two way configurable system bi amplified or passive full range using a subwoofer of 12 compression driver M78N with exit of 1 5 and titanium diaphragm To improve the acoustic response it is equipped with two horns ...

Page 7: ...s User s Manual HQ 112 95 Two way system with 2 selectable operating modes passive system or Bi amplified system 12 bass loudspeaker Compression driver with titanium diaphragm Rotatable 90º x 50º horn design Trapezoid geometry enclosure Finish CX covered exposure and DX direct exposure 20 built in rigging points The HQ 112 95 is a two way configurable system bi amplified or passive full range usin...

Page 8: ...X 4x HQ 112 xx horizontal array 4x HQ 112 95 2x HQ 218 horizontal array PRC Power Reduction Control for D 100 PRC 0 dB for HQ 218 PRC 4 dB for HQ 112 xx Next you will see three examples You will find more configurations on our website DSP 2060A D100 LINK HQ 112 95 HQ 112 95 HQ 218 LINK HQ 112 95 HQ 112 95 HQ 218 ...

Page 9: ...n Control for D 100 PRC 0 dB for HQ 218 PRC 4 dB for HQ 112 xx Nota Para acoplamiento acústico óptimo el usuario debe girar los difusores de MF y HF como se explica en las figuras abajo Note For optimal acoustic coupling the user must rotate MF and HF horns as explained on images below Factory horns settings for the HQ 112 43 Horns settings for vertical arrays with HQ 112 43 40º 30º 90º 50º 50º 40...

Page 10: ... Fiberglass Military Grey Pantone 402C CX black paint DX Fiberglass Military Grey Pantone 402C CX black paint DX Fiberglass Military Grey Pantone 402C CX black paint DX Fiberglass Military Grey Pantone 402C Rigging points 20 x M10 threaded hardware 20 x M10 threaded hardware 20 x M10 threaded hardware 20 x M10 threaded hardware Weather Resistance Level Covered Exposure CX Direct Exposure DX Covere...

Page 11: ...11 LINE DRAWINGS Manual del Usuario HQ series User s Manual HQ 112 43 HQ 112 64 HQ 112 95 HQ 218 ...

Page 12: ...ost types of installations These terminals are connected in parallel so that we can carry the amplified audio signal up to a device and we can forward it to the next box very easily The polarity of the connectors and other important information for proper connection is indicated on the labels The HQ 112 xx models of the D A S HQ series have been provided with rotatable horns to optimize the acoust...

Page 13: ...he D A S HQ series is designed with trapezoid enclosures to very easily achieve the desired coverages in fixed installations Here are some basic examples Vertical Array 70º coverage VISTA LATERAL SIDE VIEW VISTA LATERAL SIDE VIEW Vertical Array 110º coverage ...

Page 14: ...anual del Usuario HQ series User s Manual Horizontal Array 100º coverage Horizontal Array 60º coverage Horizontal Array 150º coverage VISTA SUPERIOR TOP VIEW VISTA SUPERIOR TOP VIEW VISTA SUPERIOR TOP VIEW ...

Page 15: ...binations to achieve the desired coverage in each installation We have collected only the most indicative examples given the infinite possibilities On our website you can find the gll files for Ease Focus software with which you can simulate the acoustic performance of a given configuration of devices For instance VISTA SUPERIOR TOP VIEW ...

Page 16: ...s must be met 5 1 for steel cable slings 4 1 for steel chain slings and 7 1 polyester slings Thus an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 Kg 7 1 safety factor The load capacity of each lift motor should be correspond to a safety factor of 10 1 When flying a system the working load must be lower than the...

Page 17: ...n milimetres Each ANL 2 eyebolt has a rated working load of 200 kg 440 lb Each ANL 2 carabiner has a working load of 330 kg 726 lb If using other hardware make sure it is rated to handle the required load When using eyebolts it is important to bear in mind that the rated working load is only true for a load applied in the plane of the eye and is significantly reduced for other angles The drawing i...

Page 18: ...18 Manual del Usuario HQ series User s Manual Horizontal array 2x HQ 112 xx 1x HQ 218 Vertical array 3x HQ 112 xx Vertical array 3x HQ 112 xx 1x HQ 218 ...

Page 19: ...in and dB for different cable lengths and sections shown It is recommended that the losses do not exceed 30 in any case around 3dB Although it is recommended minimizing losses the maximum acceptable losses are usually around 15 approximately 1 4dB ANNEX Table for cable selection ...

Page 20: ...6900 NW 52th Street Miami FL 33166 U S A TOLL FREE 1 888 DAS 4 USA D A S AUDIO ASIA PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 D A S AUDIO S A C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 ...

Reviews: