Cytech Comfort DM02 Manual Download Page 1

C

om

for

t, the

   

In

te

llige

n

t   H

om

e   Sy

st

em

 

Comfort

DM02 Door

Station

Interface

Summary of Contents for Comfort DM02

Page 1: ...Comfort the Intelligent Home System Comfort DM02 Door Station Interface...

Page 2: ......

Page 3: ...Specifications 2 Contents 2 Differences from DM01 2 Settings 2 Connections 2 Jumper Settings 2 LED Indicators 3 Trimmers 3 Switch 3 Door Station ID Switch 3 Installation Examples 5 Typical Fermax Inst...

Page 4: ......

Page 5: ...outdoor call station or DP04 will be used The DM02 module is mounted within or next to the main Comfort control panel When a visitor presses the doorbell on the intercom call station the Intercom Ind...

Page 6: ...onse w JP4 COM1 NO1 NC1 Terminals for Relay Contact for Open Gate Response w JP3 BELL GND 12V_OUT Connector for Doorbell Input 5 to 24 VAC or 5 to 24 VDC voltage input initiates the doorbell If doorbe...

Page 7: ...mulates a press of the doorbell for testing Door Station ID Switch Comfort is able to support up to 3 door stations SW1 is a set of 3 headers which is used to determine the ID in accordance to the fol...

Page 8: ...gineer Menu 7 4 1 and set location 1674 to the number of door stations The system must be reset in both cases for the changes to take effect If any door station loses communications with Comfort it wi...

Page 9: ...SPK MIC SPK KA KB OUT IN OUT OUT IN GND 12V_IN JP 5 JP 4 JP 3 JP 2 JP 7 JP 6 JP1 JP 8A JP 8 A B C SW1 SW2 MIC VR1 J5 J2 TONE J1 VOICE VR2 C24 C7 C8 D8 2 1 3 4 6 Fermax Indoor Unit 2 1 3 6 Fermax Outd...

Page 10: ...udio from indoor to outdoor 3 GND COM2 Common Ground Shorted with 1 to trigger electric lock 4 and L BELL Call wire sends signal when pushbutton is pressed 6 MIC IN Audio from outdoor to indoor Note t...

Page 11: ...2 COM1 NO1 NC1 BELL GND 12V MIC SPK MIC SPK KA KB OUT IN OUT OUT IN GND 12V_IN JP 5 JP 4 JP 3 JP 2 JP 7 JP 6 JP1 JP 8 A JP 8 A B C SW1 SW2 MIC VR1 J5 J2 TONE J1 VOICE VR2 C24 C7 C8 D8 In the Farfisa i...

Page 12: ...ef summary is shown below Farfisa DM02 Remarks 1 SPK OUT Reception audio line audio to door station 2 MIC IN Transmission audio line audio from door station 3 12V OUT Power supply 4 GND Audio ground G...

Page 13: ...rotects Comfort from any damage due to nearby lighting surges as this would tend to affect the DP04 only while the DM02 in the house may not be affected C4 C2 U2 U1 C6 VR1 MIC SPK 12V COM DOOR BELL PC...

Page 14: ...erface The rest of the connections are as follows DP04 DM02 Remarks MIC MIC IN Microphone audio from DP04 SPK SPK OUT Speaker audio to DP04 12V 12V OUT 12V supply to DP04 COM GND GND to DP04 DOOR BELL...

Page 15: ...2 Door Station Interface Version History 1 0 2 3 March 2007 Changed to DM02 Includes support for voltage free contacts for doorbell support for DP04 audio module 1 0 0 14 October 2003 Initial Release...

Page 16: ...r Station Interface Document Title Comfort DM02 Door Station Interface Filename DMman doc Document Version 1 0 2 Date Last Modified 2 March 2007 Comfort Version Outside 4 202 and above Comfigurator 1...

Reviews: