Cypress SPX-5601C(1) Operation Manual Download Page 1

      

Page 1 of 20

SPX-5600MAN

SPX-5600 Series

Suprex® Reader Extender - RF Wireless Interface

Operations Manual

Summary of Contents for SPX-5601C(1)

Page 1: ...Page 1 of 20 SPX 5600MAN SPX 5600 Series Suprex Reader Extender RF Wireless Interface Operations Manual...

Page 2: ...nal status of the unit Auxiliary I O connections available for Door Gate Panel status signaling Multiplexing of RF bridge providing for additional door gate on a single RF link Economical expansion ca...

Page 3: ...Dorad0 644 Strobed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON 1 2 3 4 5 6 7 8 Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 ON Service...

Page 4: ...C R1 Com R1 N O Card Reader D0 Clock D1 Data LED DC Power Supply SPX 5600 Series Central Quick Reference Typical Suprex Central Connections Suprex Central 1 2 3 4 5 6 7 8 Wiegand Wiegand No Filter Str...

Page 5: ...ruction ACS Typical RF installation with repeater Typical RF installation line of sight SPX 5601C 1 SPX 5651 ACS SPX 5601C 1 SPX 5601R 1 EXP 1000R 3 EXP 1000R 2 SPX 5601R 1 SPX 5601R 1 Typical RF inst...

Page 6: ...de rating curve The Suprex units should be operated with a filtered 12 Volt nominal DC supply Any voltage between 8 and 16 volts can be utilized by following the temperature voltage derating curve Vo...

Page 7: ...Page left intentionally blank Page 7 of 20...

Page 8: ...unit was shipped without antennas installed 2 Connect a suitable power supply to both units Each unit should be provided with 8 16 volts DC and approx 300mA Both units should be separated by a minimum...

Page 9: ...l is not Receiving communication from the Remote Operating modes By setting DIP switch 1 to the ON position the unit is placed in Setup Config mode When the switch position is changed cycle power to t...

Page 10: ...ction There are two relays available for accessory outputs at the Remote end Either relay can be used to provide the Door Strike or Gate activation function This example uses Relay 1 Wiring Example Do...

Page 11: ...re floating nothing connected the associated output will be set to a high level When the input is set to 0Volts Ground the input will activate its associated output All Accessory outputs are Open Coll...

Page 12: ...Page 12 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 1 IN Input Signal Relay 1 N C Relay 1 Com Relay 1 N O Suprex Remote Contact Outputs...

Page 13: ...Page 13 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 2 IN Input Signal Relay 2 N C Relay 2 Com Relay 2 N O Suprex Remote Contact Outputs...

Page 14: ...rm relay and monitors the condition of the communication link between the Central and Remote units Relay 3 is activated when power is applied and the communication link between the Central and Remote...

Page 15: ...Page 15 of 20 Cypress Suprex Series Relay Controls Suprex Central Relay 4 N C Relay 4 Com Relay 4 N O Suprex Remote Contact Outputs Relay 4 IN Input Signal 5Volts DC Maximum...

Page 16: ...orientation of the antenna will determine what is referred to as the polarization of the signal Significant reduction in range can result if the units are not oriented with the same polarity See below...

Page 17: ...uctions and is placed away from metal objects This orientation may reduce range The metal pole is placed between antenna and other unit and the antenna is close to metal Better improved range Antenna...

Page 18: ...ock Out RLY4 N O RLY4 Com RLY4 N C RLY3 N O RLY3 Com RLY3 N C RS232 Out RS232 In Ground Aux Out Relay2 Input Relay1 Input Access Control Panel Ground 8 to 16 VDC D0 Clock Out D1 Data Out LED In 485 48...

Page 19: ...1000 Remote Unit 8 to 16 VDC In Ground RLY2 N O RLY2 Com RLY2 N C RLY1 N O RLY1 Com RLY1 N C RS232 Out RS232 In Ground Aux In N C N C 485 485 5 VDC Out RLY4 Input 5V RLY3 Input 5V LED Output D1 Data F...

Page 20: ...Page left intentionally blank Page 20 of 20...