SPX-5500SS

SPX-5500 Series

RF 900Mhz Suprex® Reader 

Operations Manual

SPX-5511 pictured

Summary of Contents for SPX-5500 Series

Page 1: ...SPX 5500SS SPX 5500 Series RF 900Mhz Suprex Reader Operations Manual SPX 5511 pictured...

Page 2: ...any interference received including interference that may cause undesired operation Overview The SPX 5500 series of RF Wireless solutions provide a wireless bridge from card readers with gates or door...

Page 3: ...obed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 ON Service Mode DIP Switch 1 OFF Quiet M...

Page 4: ...N C R1 Com R1 N O Card Reader LED DC Power Supply SPX 5000 Series Central Quick Reference Typical Suprex Central Connections Suprex RF Central 1 2 3 4 5 6 7 8 Wiegand Wiegand No Filter Strobed Rising...

Page 5: ...r 100mW Receive Sensitivity 110 dBm Interference Rejection 70dB Antenna Options and typical range Internal Up to 500 feet SPX 5501 Dipole up to 1 Mile SPX 5511 Yagi Up to 12 000 feet SPX 5531 Distance...

Page 6: ...h Test 1 Connect any antennas if the unit has a removable type antenna such as a dipole or Yagi 2 Connect a suitable power supply to both units Each unit should be provided with 8 16 volts DC and appr...

Page 7: ...NTRAL UNITS FLASHING BETWEEN RED GREEN The Central is not Receiving communication from the Remote Operating modes By setting DIP switch 1 to the ON position the unit is placed in Setup Config mode Whe...

Page 8: ...tion of the antenna will determine what is referred to as the polarization of the signal Significant reduction in range can result if the units are not oriented with the same polarity See below Both C...

Page 9: ...and is placed away from metal objects This orientation may reduce range The metal pole is placed between antenna and other unit and the antenna is close to metal Better improved range Antenna has lin...

Page 10: ...ect as shown below These connections can be used to allow the Remote relay to operate a DOOR STRIKE GATE or other locking hardware Refer to following pages in this document for details of each I O ope...

Page 11: ...ing nothing connected the associated output will be set to a high level When the input is set to 0 Volts Ground the input will activate its associated output All Accessory outputs are Open Collector t...

Page 12: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 1 IN Input Signal Relay 1 N C Relay 1 Com Relay 1 N O Suprex RF Remote Contact Outputs...

Page 13: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 2 IN Input Signal Relay 2 N C Relay 2 Com Relay 2 N O Suprex RF Remote Contact Outputs...

Page 14: ...relay and monitors the condition of the communication link between the Central and Remote units Relay 3 is activated when power is applied and the communication link between the Central and Remote is...

Page 15: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 4 N C Relay 4 Com Relay 4 N O Suprex RF Remote Contact Outputs Relay 4 IN Input Signal 5Volts DC Maximum...

Page 16: ...Cypress Suprex RF Series Auxillary I O Suprex RF Central Suprex RF Remote Aux Output Signal AUX IN AUX OUT Aux Input Signal...