![Cypress PSoC 1 CY3210-PSoCEVAL1 Manual Download Page 46](http://html1.mh-extra.com/html/cypress/psoc-1-cy3210-psoceval1/psoc-1-cy3210-psoceval1_manual_2706286046.webp)
CY3210-PSoCEVAL1 PSoC® 1 Evaluation Kit Guide, Doc. #: 001-66768 Rev. *F
46
Code Examples
b. In the Program Part window, configure the following settings:
Port Selection: Select
MiniProg1/xxxxxxxxxxx
and then
Connected
Acquire Mode:
Power Cycle
Verification:
Off
Power Settings:
5.0 V
c. Click on the
Program
button (see
) to start programming the board.
d. Observe the programming status on the progress bar.
Figure 5-29. Programming Status
e. When programming is successful, the 'Operation Succeeded!' message is displayed.
Figure 5-30. Operation Succeeded!' Message
5.1.3
Verifying Output using LCD
1. Set up the board with the following connections using the jumpers (shunts) and single strand
jumper wires:
a. Connect P01 to VR using a single strand jumper wire. This connects one of the PSoC pins to
the potentiometer.
b. Place jumper (shunt) on JP1 to connect P16 and Rx.
c. Place jumper (shunt) on JP2 to connect P27 and Tx.
d. Connect an RS-232 cable from connector J1 to a COM port on the PC.
e. Remove jumper (shunt) JP3 to operate the board at 5 V. The LCD display is seen for 5 V
operation only.
2. Power the board by clicking on the
Toggle Power
) in the Program Part
window.
3. The ADC value is shown on the LCD display. A bar graph corresponding to the ADC value is also
displayed. The ADC value varies from 0000-0FFF for input voltage of 0 V to 5 V. The input volt-
age can be varied by rotating the potentiometer (R7) connected to VR.