MB95710M Series
MB95770M Series
Document Number: 002-09307 Rev. *D
Page 143 of 172
22.4.2 Source Clock/Machine Clock
(V
CC
= 1.8 V to 5.5 V, V
SS
= 0.0 V, T
A
=
−
40 °C to
+
85 °C)
Parameter
Symbol
Pin
name
Value
Unit
Remarks
Min
Typ
Max
Source clock
cycle time*
1
t
SCLK
—
61.5
—
2000
ns
When the main external clock is used
Min: F
CH
= 32.5 MHz, divided by 2
Max: F
CH
= 1 MHz, divided by 2
—
250
—
ns When the main CR clock is used
62.5
—
250
ns
When the main PLL clock is used
Min: F
CH
= 4 MHz, multiplied by 4
Max: F
CH
= 4 MHz, no division
62.5
—
250
ns
When the main CR PLL clock is used
Min: F
CRH
= 4 MHz, multiplied by 4
Max: F
CRH
= 4 MHz, no division
—
61
—
µs
When the sub-oscillation clock is used
F
CL
= 32.768 kHz, divided by 2
—
20
—
µs
When the sub-CR clock is used
F
CL
= 100 kHz, divided by 2
Source clock
frequency
F
SP
—
0.5
—
16.25
MHz When the main oscillation clock is used
—
4
—
MHz When the main CR clock is used
8
—
16
MHz When the main PLL clock is used
8
—
16
MHz When the main CR PLL clock is used
F
SPL
—
16.384
—
kHz When the sub-oscillation clock is used
—
50
—
kHz
When the sub-CR clock is used
F
CRL
= 100 kHz, divided by 2
Machine clock
cycle time*
2
(minimum
instruction
execution time)
t
MCLK
—
61.5
—
32000
ns
When the main oscillation clock is used
Min: F
SP
= 16.25 MHz, no division
Max: F
SP
= 0.5 MHz, divided by 16
250
—
4000
ns
When the main CR clock is used
Min: F
SP
= 4 MHz, no division
Max: F
SP
= 4 MHz, divided by 16
62.5
—
2000
ns
When the main PLL clock is used
Min: F
SP
= 4 MHz, multiplied by 4
Max: F
SP
= 4 MHz, divided by 16
62.5
—
2000
ns
When the main CR PLL clock is used
Min: F
SP
= 4 MHz, multiplied by 4
Max: F
SP
= 4 MHz, divided by 16
61
—
976.5
µs
When the sub-oscillation clock is used
Min: F
SPL
= 16.384 kHz, no division
Max: F
SPL
= 16.384 kHz, divided by 16
20
—
320
µs
When the sub-CR clock is used
Min: F
SPL
= 50 kHz, no division
Max: F
SPL
= 50 kHz, divided by 16