background image

Wiring Diagram #4 Strobed to Serial 

The Strobed to RS232 converters support incoming commands to
control the Reader LED and Converter Relay.

RX Data:

NOTE: Commands must be capitalized characters
  Turn LED on................ 

@ L 1

  Turn LED off............... 

@ L 0

  Toggle LED................. 

@ L 2

 

(Bi-Color LED Turns Orange)

  Turn Relay on.............. 

@ R 1

  Turn Relay off............. 

@ R 0

CVX Terminal

DB9 Pin

Ground

5

RS232 Input

3

RS232 Output

2

DB-9 Connections
Direct to PC Com Port

Reader powered by external supply (8 to 16 VDC)

Connections 

to Serial 

Device

Card 

Reader

D0/Clock In
D1/Data In
LED Out
Ground
RS232 Input
RS232 Output

Ground

+8 to +16 VDC In

Data Bender®

Clock

Strobe
LED
Ground

DC

Power 

Supply

(-)

(+)

Summary of Contents for DataBender CVX-1300

Page 1: ...CVX 1300_MAN_112011 CVX 1300 Operations Manual DataBender Universal Format Converter ...

Page 2: ...l Dimensions and Mounting Holes Unit Height 0 75 Electrical and Mechanical Specifications See notes on following page for temperature and power ratings This complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesire...

Page 3: ...onnections and operation 2 Set the DIP switch to the setting called out in the CVX application chart 3 Refer to the wiring diagram for the particular converter that is being used The wiring diagrams are different depending upon the type of conversion being performed 4 Connect power to the CVX 1300 board 5 If the diagnostic indicator LED flashes Green slowly a valid converter number has been select...

Page 4: ...6 volts can be utilized by following the temperature voltage derating curve Voltage should not exceed 16 VDC under normal operating conditions DC Power IN Converter CVX 1300 CYPRESS Ground 8 to 16 VDC In 1 D0 CLK Input 2 D1 Data Input 3 Aux2 LED Out 4 Ground 5 RS232 Input 6 RS232 Output 7 RLY1 N C 8 RLY1 Com 9 RLY1 N O 10 RLY2 N C 11 RLY2 Com 12 RLY2 N O 1 D0 CLK Output 2 D1 Data Output 3 Aux1 LED...

Page 5: ...www cypressoworld com A Diagnostic LED is provided to provide operational status of the converter Diagnostic LED OFF No power Diagnostic LED Blinking Green Unit is operating Diagnostic LED Red Undefined DIP Switch Setting Note Terminals shown for reference Connections may or may not be utilized based on converter function External connections and product description Converter CVX 1300 1 D0 CLK Inp...

Page 6: ... 232 or RS 485 interface The baud rate will be determined by the DIP switch setting The CVT 9110 function will provide a Wiegand input and a serial output Serial data will be output on the RS 232 and RS 485 interface NOTE Some of the CVX 1300 converters may not support both RS 232 and RS 485 interfaces Converters that do not support both interfaces will be noted in the specific converter specifica...

Page 7: ...This Page left intentionally blank ...

Page 8: ... 65 66 67 CVT 9110 Serial 12 Hex Wiegand Variable 68 68 70 CVT 9109 Serial Transcore Wiegand 26 71 CVT 9129 Serial Transcore Xico 6 72 CVT 9132 Serial Transcore Wiegand 37 73 CVT 9137 Serial Transcore Wiegand 26 74 CVT 9117 Serial Transcore Wiegand 26 75 CVT 9161 Serial Transcore Wiegand 26 76 CVT 9162 Serial Transcore Wiegand 37 77 CVT 9164 Serial Transcore Wiegand 37 78 CVT 9201 Serial ASCII Str...

Page 9: ...9501 Serial ASCII 1 12 digits F 2F 83 CVT 2485 Wiegand 24 40 Serial ASCII RS 485 1 2 3 CVT 9485 Serial ASCII RS 485 Wiegand 24 40 65 66 67 CVT 2201F Strobed ABA Fall Edge Serial 24 Hex 37 CVT 5100F Strobed ABA Fall Edge Wiegand 26 bit 106 CVT 5100AF Strobed ABA Fall Edge Wiegand 26 bit 107 CVX 2232 5 Wiegand 24 40 Serial Last 5 digits 38 CVX 9174 Serial ASCII 1 10 Dec Wiegand 37 Bit FC 1 87 CVT 01...

Page 10: ... 232 1200 Hex Digits 13 X X X Wiegand 44 bits RS 232 9600 12 Digits 14 X X X Wiegand 44 bits RS 232 2400 12 Digits 15 X X X X Wiegand 44 bits RS 232 1200 12 Digits 16 X Wiegand 44 32 bits RS 232 9600 12 10 Digits 17 X X Wiegand 44 32 bits RS 232 2400 12 10 Digits 18 X X Wiegand 44 32 bits RS 232 1200 12 10 Digits 19 X X X Wiegand 1 to 96 bits RS 232 9600 24 Hex Dec 20 X X Wiegand 1 to 96 bits RS 2...

Page 11: ... X X Wiegand ABA RS 232 9600 ASCII 36 X X Wiegand ABA RS 232 2400 ASCII 37 X X X Strobed Fall ABA RS 232 9600 24 Hex ASCII 38 X X X Wiegand 24 to 40 bits RS 232 9600 5 Digits CR 39 X X X X Radionics Readykey Wiegand 40 Bit 40 X X Radionics Readykey Wiegand 34 Bit 41 X X X Radionics Readykey Wiegand 26 Bit 42 X X X 43 X X X X 44 X X X 45 X X X X 46 X X X X 47 X X X X X 48 X X 49 X X X 50 X X X 51 X...

Page 12: ...RS 232 9600 TransCore Wiegand 26 75 X X X X RS 232 9600 TransCore Wiegand 26 9117 76 X X X RS 232 9600 TransCore Wiegand 26 9161 77 X X X X RS 232 9600 TransCore Wiegand 37 78 X X X X RS 232 9600 TransCore Wiegand 37 79 X X X X X RS 232 9600 ASCII Strobed ABA 80 X X RS 232 2400 ASCII Strobed ABA 81 X X X RS 232 1200 ASCII Strobed ABA 82 X X X RS 232 9600 ASCII Strobed NoPU ABA 83 X X X X RS 232 96...

Page 13: ...99 X X X X Wiegand 35 bit Wiegand 26 bit 100 X X X Strobed ABA 12 digits Wiegand 26 bit 101 X X X X Strobed ABA Last 8 dig Wiegand 26 bit 102 X X X X Wiegand 26 bit Strobed ABA 12 digits 103 X X X X X 104 X X X 105 X X X X 106 X X X X 107 X X X X X 108 X X X X 109 X X X X X 110 X X X X X 111 X X X X X X 112 X X X 113 X X X X 114 X X X X 115 X X X X X 116 X X X X 117 X X X X X 118 X X X X X 119 X X...

Page 14: ...nd 3 Wiegand to Wiegand 4 Strobed to Serial 5 Serial to Strobed 6 Strobed to Wiegand 7 Wiegand to Strobed 8 F 2F to Wiegand 9 Serial to F2F 10 Dallas iButton to Wiegand 11 Serial to Wiegand Special Application 12 Radionics 1 Wire to Wiegand This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 ...

Page 15: ...n LED off L 0 Toggle LED L 2 Bi Color LED Turns Orange Turn Relay on R 1 Turn Relay off R 0 CVX Terminal DB9 Pin Ground 5 RS232 Input 3 RS232 Output 2 DB 9 Connections Direct to PC Com Port Connections to Serial Device D0 Clock In D1 Data In LED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Card Reader Data0 Data1 LED Ground DC Power Supply Reader powered by external supply...

Page 16: ...urn LED off L 0 Toggle LED L 2 Bi Color LED Turns Orange Turn Relay on R 1 Turn Relay off R 0 CVX Terminal DB9 Pin Ground 5 RS232 Input 3 RS232 Output 2 DB 9 Connections Direct to PC Com Port Reader powered by converter 5 VDC Connections to Serial Device D0 Clock In D1 Data In LED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Card Reader Data0 Data1 LED Ground DC Power Supp...

Page 17: ...erial to Wiegand Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Data0 Out Data1 Out Connections to Serial Device DB9 5 DB9 2 DB9 3 DB9 6 DC Power Supply Access Control Panel Data0 Data1 Ground 5VDC Out ...

Page 18: ...Data 0 Data 1 Ground Access Control Panel D0 Input D1 Input Ground Ground 8 to 16 VDC In Data Bender D0 Output D1 Output Reader powered by 5 Volt Supply Card Reader Data0 Data1 Ground D0 Input D1 Input Ground Ground 8 to 16 VDC In Data Bender D0 Output D1 Output DC Power Supply Data 0 Data 1 Ground Access Control Panel 5 VDC Out ...

Page 19: ...n LED off L 0 Toggle LED L 2 Bi Color LED Turns Orange Turn Relay on R 1 Turn Relay off R 0 CVX Terminal DB9 Pin Ground 5 RS232 Input 3 RS232 Output 2 DB 9 Connections Direct to PC Com Port Reader powered by external supply 8 to 16 VDC Connections to Serial Device Card Reader D0 Clock In D1 Data In LED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Clock Strobe LED Ground DC...

Page 20: ...rn LED off L 0 Toggle LED L 2 Bi Color LED Turns Orange Turn Relay on R 1 Turn Relay off R 0 CVX Terminal DB9 Pin Ground 5 RS232 Input 3 RS232 Output 2 DB 9 Connections Direct to PC Com Port Reader powered by converter 5 VDC Connections to Serial Device Card Reader D0 Clock In D1 Data In LED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Clock Strobe LED Ground DC Power Supp...

Page 21: ...o Strobed DC Power Supply Access Control Panel Clock Data Ground Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Clock Out Data Out Connections to Serial Device DB9 5 DB9 2 DB9 3 DB9 6 5 Volts If Used 5VDC Out ...

Page 22: ...ED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Clock Strobe LED Ground DC Power Supply Data 0 Data 1 Ground Access Control Panel Connections to Serial Device Card Reader D0 Clock In D1 Data In LED Out Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Clock Strobe LED Ground DC Power Supply 5VDC Out Data 0 Data 1 Ground Access Control Panel ...

Page 23: ...Clock Data Ground Access Control Panel D0 Clock In D1 Data In Ground Ground 8 to 16 VDC In Data Bender Clock Out Data Out Reader powered by 5 Volt Supply Access Control Panel DC Power Supply Clock Data Ground D0 Clock In D1 Data In Ground Ground 8 to 16 VDC In Data Bender Clock Out Data Out Card Reader Data0 Data1 Ground 5VDC Out ...

Page 24: ...ard Reader DC Power Supply Access Control Panel F2F Input Ground Ground 8 to 16 VDC In Data Bender D0 Output D1 Output Reader powered by 5 Volt Supply Card Reader DC Power Supply Data 0 Data 1 Ground Access Control Panel F2F Ground F2F Input Ground Ground 8 to 16 VDC In Data Bender D0 Output D1 Output 5 VDC Out ...

Page 25: ...iagram 9 Serial to F2F Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender F2F Output Connections to Serial Device DB9 5 DB9 2 DB9 3 DB9 6 DC Power Supply Access Control Panel F2F Ground 5VDC Out ...

Page 26: ...m 10 IButton to Wiegand Data 1 Data 0 Ground DC Power Supply Access Control Panel IButton Center Contact Ground IButton Reader 4 7 k Pullup Resistor Data In Data In Ground Ground 8 to 16 VDC In Data Bender 5VDC Out ...

Page 27: ...iegand Special Application Ground RS232 Input RS232 Output Ground 8 to 16 VDC In Data Bender Data0 Out Data1 Out Connections to Serial Device DB9 5 DB9 2 DB9 3 DB9 4 DC Power Supply Access Control Panel Data0 Data1 Ground 5VDC Out ...

Page 28: ...y 8 to 16 VDC 2 7 k Pullup Resistors Must be installed as shown Resistor values between 1k and 10k should work Both resistors should be the same value Data Out SIG DC Power Supply Access Control Panel Card Reader VDC V Ground V Ground 8 to 16 VDC In Data Bender D0 Output D1 Output 5VDC 485 485 ...

Reviews: