CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E
50
FINGER_THRESHOLD10
0x16
1.5.19
FINGER_THRESHOLD10
Address = 0x16
Finger threshold (units: counts) applied for sensor 10 when automatic threshold mode is disabled. Note that this threshold is
also applied when EMC is enabled, as automatic threshold is disabled when EMC is enabled. This register is not applicable
for parts CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
Address: 0x16
Bits
7
6
5
4
3
2
1
0
Host Access
RW
Device Access
RW
Bit Name
FINGER_THRESHOLD10
Bits
Name
Description
7 : 0
FINGER_THRESHOLD10
Finger threshold (units: counts) applied for sensor 10 when automatic threshold mode is dis-
abled. Note that this threshold is also applied when EMC is enabled, as automatic threshold is
disabled when EMC is enabled. The valid value of this bit field ranges from 31 to 200. This bit
field is not applicable for parts CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.