CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E
127
SNS_SNS_SHORT
0x9e
1.5.93
SNS_SNS_SHORT
Address = 0x9e
Indicators of sensors with short circuit to another sensor or shield. If System diagnostics feature is disabled
(DEVICE_CFG1.SYSD_EN = 0), this register's content is invalid.
Address: 0x9e
Bits
15
14
13
12
11
10
9
8
Host Access
R
R
R
R
R
R
R
R
Device Access
RW
RW
RW
RW
RW
RW
RW
RW
Bit Name
CS15
CS14
CS13
CS12
CS11
CS10
CS9
CS8
Bits
7
6
5
4
3
2
1
0
Host Access
R
R
R
R
R
R
R
R
Device Access
RW
RW
RW
RW
RW
RW
RW
RW
Bit Name
CS7
CS6
CS5
CS4
CS3
CS2
CS1
CS0
Bits
Name
Description
15
CS15
Sensor 15 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
14
CS14
Sensor 14 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
13
CS13
Sensor 13 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
12
CS12
Sensor 12 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
11
CS11
Sensor 11 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
10
CS10
Sensor 10 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108, CY8CMBR3110.
0:
No short circuit to another sensor or shield, or sensor not tested
1:
Short circuit to another sensor or shield detected
9
CS9
Sensor 9 short to another sensor indicator. This bit field is not applicable for parts
CY8CMBR3102, CY8CMBR3108.