CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E
110
SENSOR_ID
0x82
1.5.79
SENSOR_ID
Address = 0x82
Sensor ID for which to report sensor debug data. The valid values of this register depend on the number of sensors in the
part, valid values for a part are 0 to (number of sensors - 1).
Address: 0x82
Bits
7
6
5
4
3
2
1
0
Host Access
RW
Device Access
RW
Bit Name
SENSOR_ID
Bits
Name
Description
7 : 0
SENSOR_ID
Sensor ID for which to report sensor debug data.
The register's default value is an invalid value which is 255. The valid value of this bit field ranges
from 0 to 15.