CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E
158
GPO_DATA
0xda
1.5.120
GPO_DATA
Address = 0xda
GPO state values that the device is outputting. If GPOs are outputting PWM, these bits reflect the duty cycle selection (LOW
or HIGH). Bits corresponding to disabled GPO are 0. This register is not applicable for part CY8CMBR3106S.
Address: 0xda
Bits
7
6
5
4
3
2
1
0
Host Access
R
R
R
R
R
R
R
R
Device Access
RW
RW
RW
RW
RW
RW
RW
RW
Bit Name
GPO7
GPO6
GPO5
GPO4
GPO3
GPO2
GPO1
GPO0
Bits
Name
Description
7
GPO7
GPO7 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
6
GPO6
GPO6 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
5
GPO5
GPO5 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
4
GPO4
GPO4 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
3
GPO3
GPO3 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
2
GPO2
GPO2 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
1
GPO1
GPO1 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle
0
GPO0
GPO0 value indicator. This bit field is not applicable for part CY8CMBR3106S.
0:
Low DC output/PWM duty cycle
1:
High DC output/PWM duty cycle