background image

 
 

 

SMART

 E

N

ER
G

Y CO

N

TROL
 

NEXUS SERIES 

HARDWARE INSTALLATION GUIDE

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Aspect-Nexus 2

Page 1: ...SMART ENERGY CONTROL NEXUS SERIES HARDWARE INSTALLATION GUIDE...

Page 2: ...those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for a...

Page 3: ...ont For example BACnet Code Text that represents File paths Code snippets or text file configuration settings is presented in fixed width font with a grey background and border For example config_file...

Page 4: ...ries device on the wall 16 Mounting the NEXUS Series device on a DIN rail 17 SECTION 3 DETAILED ENGINEERING SPECIFICATIONS Dimensions and weight 20 Product dimensions and weight 20 Packaging dimension...

Page 5: ...Administration 34 SQLite Maintenance 35 Licensing 35 Communication Setup 36 Out Of Service Manager OSS 36 BACnet Settings 36 BBMD Settings 37 Modbus Network Properties 37 Time Sync Settings 37 System...

Page 6: ...6 Cylon Controls MAN0125 Rev 19 NEXUS Series This page is intentionally blank...

Page 7: ...SECTION 1 OVERVIEW...

Page 8: ...LED Unused 5 Cloud connection status LED unused 6 Port D status LEDs Unused 7 Network 1 status LEDs Indicates the connectivity status and network activity Orange 100Mb s 10 100 Green 1000Mb s Gigabit...

Page 9: ...an Ethernet RJ45 cable from a router or a broadband modem for network or internet access 9 Port D Recovery Ethernet Port BOTTOM PANEL DIP SWITCHES 1 RS485 port 1 resistor switch Enable disable the di...

Page 10: ...nd antenna port port two Unused 4 Wi Fi antenna port port three Unused 5 Intrusion detection connector Unused 6 Wi Fi antenna port port four Unused 7 HDMI port Connect a monitor or other HDMI device P...

Page 11: ...e included Dell PSU When using a higher VA transformer care must be taken to ensure that the voltage stays within specification see Detailed Engineering Specifications Power on page 22 Warning Earthin...

Page 12: ...12 Cylon Controls MAN0125 Rev 19 NEXUS Series This page is intentionally blank...

Page 13: ...SECTION 2 INSTALLATION AND CONFIGURATION...

Page 14: ...Connect a network cable 3 Connect a SELV limited energy circuit power source 24 V AC DC or 19 5 V DC to the NEXUS Series device and press the power button to turn it on Note For warranty purposes it i...

Page 15: ...ed with each NEXUS Series device and for warranty purposes must be installed as described below Each RS485cable must be plugged into a surge protector and the protector plugged into one of the NEXUS S...

Page 16: ...ately 1 Secure the two mounting brackets to the back of the NEXUS Series device by using four screws 2 Drill four holes in the wall that correspond to the holes in the mounting bracket then place the...

Page 17: ...ts to the back of the NEXUS Series device 1 Align the screw holes on the DIN rail mount to the back of the NEXUS Series device place the screws on the DIN rail mount and secure it to the NEXUS Series...

Page 18: ...18 Cylon Controls MAN0125 Rev 19 NEXUS Series This page is intentionally blank...

Page 19: ...SECTION 3 DETAILED ENGINEERING SPECIFICATIONS...

Page 20: ...in Note The dimensions for the enclosure do not include the latches and wall bracket on the back of the enclosure The wall bracket adds 5 mm 0 04 inches to the depth PACKAGING DIMENSIONS AND WEIGHT He...

Page 21: ...operating temperature is derated 1 C 305 m 1000 ft above sea level altitude Non operating with a maximum temperature gradation of 15 C per hour 40 C 70 C 40 F 158 F Relative humidity maximum Operating...

Page 22: ...V AC DC 10 to 25 26 4 V to 18 V Note The recommended supply is a 24 V 60 VA transformer When using a higher VA transformer care must be taken to ensure that the voltage stays within specification Warn...

Page 23: ...et type Ethernet LAN 10 100 1000 External connector type RJ45 Data rates supported 10 100 1000 Mbps HARD DRIVES M 2 SATA 64GB SSD General specifications Capacity bytes 64 Gb Dimensions inches W x D x...

Page 24: ...24 Cylon Controls MAN0125 Rev 19 NEXUS Series This page is intentionally blank...

Page 25: ...SECTION 4 SOFTWARE CONFIGURATION...

Page 26: ...ed within this section for proper setup and configuration TOOLS REQUIRED The following tools will be required for proper configuration of the system PC Laptop Ethernet cross over cable or other networ...

Page 27: ...et mask 255 255 255 0 so that if connectivity is lost on the primary LANport you can use the secondary port to gain access to the NEXUS Series controller as described below and reset it Primary and Re...

Page 28: ...allation 3 If your connection is successful the main login page of ASPECT will be displayed 4 Enter the case sensitive default username and password into the fields provided 5 Click the Log In button...

Page 29: ...Project Thread Status CALENDAR CONFIGURATION The Calendar Configuration area is used to configure iCalendar integration variables of the NEXUS Series device Within this section there are two pages Ca...

Page 30: ...o the NEXUS Series device By default the username calendar and password user can be changed to any desired credential set When referencing Calendars in Aspect Studio these credentials must be specifie...

Page 31: ...y one option is available in the Instance Services drop down which will allow the instance to be reset PERSISTENCE MANAGER The Persistence Manager area is used to manage and delete Persisted data Pers...

Page 32: ...e project The required credentials will be the same as the ones used to originally deploy the project PROJECT REMOVAL The project removal page provides administrators the ability to remove a currently...

Page 33: ...icenses available for a particular feature or function PROJECT PERFORMANCE The Project Performance area provides the ability to dynamically view and monitor the status of Threads Maps and Ports being...

Page 34: ...MySQL Administration item in the webUI tree links to an administration interface for ASPECT s MySQL Database Server To access the Database Interface the user must enter case sensitive login credential...

Page 35: ...atabase This page shows the database files and sizes LICENSING The License page provides the ability to view the current license status of the NEXUS Series device as well as a method to upload downloa...

Page 36: ...erties BACnet IP Router BBMD and Time Synchronization settings OUT OF SERVICE MANAGER OSS The Out Of Service Manager OSS provides a single location that allows administrators to manually mark devices...

Page 37: ...he BACnet IP Broadcast Management Device BBMD table setup for BACnet networks MODBUS NETWORK PROPERTIES The Modbus Network Properties page is used to set the configuration for Modbus communications TI...

Page 38: ...ve users are granted full access to the Aspect Control Panel while users groups created within an instance are only allowed access to deployed projects SYSTEM SERVICES The System Services area provide...

Page 39: ...command which produces an updating list of current processes running SYSTEM UPDATES The System Updates area is used to perform firmware upgrades to the ASPECT device These firmware updates can be obt...

Page 40: ...S Series device The NEXUS Series device can support static IP addresses or DHCP addressing from a valid DHCP server Simply select the appropriate address setting for your application Toconfigurethe de...

Page 41: ...the NEXUS Series device Time and Date parameters In this section users can set the following items using the appropriate drop downs and editors System Time specified in military time System Date speci...

Page 42: ...creen and change port settings for the following Aspect Control Panel defaults to port 80 HTTP Aspect Control Engine defaults to port7226 Simple Mobile Web defaults to port8080 IMAGE PROXY CONFIGURATI...

Page 43: ...ng page is used to allow or disallow centralized syslog messaging All Aspect targets support the ability to send their log information to a centralized Aspect target or IT supported syslogserver Syste...

Page 44: ...tem Log area provides complete syslog information for the hardware Information provided within this log includes boot up details and lower level information regarding runtime of the system UPDATE LOG...

Page 45: ...MAN0125 Rev 19 Cylon Controls 45 Software Configuration This page is intentionally blank...

Page 46: ...YLON CONTROLS LTD GLOBAL HEADQUARTERS CLONSHAUGH BUSINESS TECHNOLOGY PARK CLONSHAUGH DUBLIN 17 IRELAND T 353 1 245 0500 F 353 1 245 0501 E INFO CYLON COM UK CYLON CONTROLS UK BIRMINGHAM BUSINESS PARK...

Reviews: