M4-CYG1UW-TSR-M-ENG_Iss11.docx
Cygnus UW-TSR Operating Manual
69
13.
Troubleshooting
The Gauge will not Switch On
•
Are the batteries discharged?
•
Check the battery pack is fitted correctly.
Difficulty obtaining a Reading
If there is 1 single flashing bar on the display
–
this means the
Gauge is not receiving any echoes:
•
Check that the Probe-lead is properly connected to both
Probe and Gauge.
•
Check the condition of the lead, replace if necessary.
If there is mostly 1 fixed bar plus 1 flashing bar this means that
the Gauge is having difficulty obtaining more than one echo:
•
Check the Probe and its membrane are properly assembled.
If there are up to 3 fixed bars plus 1 flashing bar, but never any
reading
–
this means the Gauge is receiving unrelated echoes from
more than one reflector:
•
On heavily corroded areas this is often a problem, try and
take measurements in adjacent areas of the same material.
•
Check the Gauge and Probe together on a test block, if there
is still no reading the Gauge may require servicing.
If Readings are Erratic or Unstable
•
Check that the Probe-lead is properly connected to both
Probe and Gauge.
•
Check that the Probe and its membrane are correctly
assembled with sufficient couplant between the probe face
and membrane.
•
Check the Probe-frequency is suitable for the probable
minimum thickness of the material being measured. Probe