The FR-300W luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire
contains an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the power in socket in the next
fixture till all are connected.
Caution: maximum power linking - 6 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color
Connection
International
Brown
Live
L
Blue
Neutral
N
Yellow/green
Earth(Ground)
Operation
The FR-300W can operate in three different modes. In each mode you can run the fixture as a stand
alone fixture or in a master/slave confiugration. This next section will detail the differences in the
operating modes.
Control Menu Map
Default setting in bold.
MAIN MENU
LEVEL 1
LEVEL 2
LEVEL 3
FUNCTION INSTRUCTION
DMX
001-512
DMX address setting
Network
DHCP
DHCP(Dynamic Host Configuration
Protocol) mode
Manual
IP address
xxx.xxx.xxx.xxx
Fixtures' IP address (assigned via
DHCP, if active)
Net Mask
255.0.0
Net Mask for class A IP address
255.255.0.0
Net Mask for class B IP address
255.255.255.0
Net Mask for class C IP address
Mode
DMX
1/2/3/4CH
DMX channel mode
ArtNet
Net
000-127
Set Art-Net net
SubNet
000-015
Set Art-Net subnet in Art-Net net
Universe
000-015
Set Art-Net universe in Art-Net
subnet
Channel
1/2/3/4CH
Art-Net channel mode
Auto
Program
001-008
Preset programs
Speed
001-009
Programs speed
Maunal
Brightness 000-255
Dimmer 0-100%
Strobe
000-255
Strobe with speed increasing
Zoom
000-255
Zoom from wide to narrow