background image

 
 
 
 
 
 
 

®

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

Serial Communications 

COMHP 7404/-D25 

PCI 4-Port Serial Interface Card, 

460.8 kbps Data Rate, 128-Byte 

FIFO Buffer, with 4 DB-9M Cable 

or 4 DB-25M Cable 

(

-D25 Model

)

 

 

 
 
 
 
 
 
 
 
 

USER’S MANUAL 

VER. 2.0C• Jun-10 

No part of this manual may be reproduced without permission 

 
 
 
 
 

 

CyberResearch

®

, Inc. 

H

www.cyberresearch.com

 

25 Business Park Dr., Branford, CT 06405 USA 

203-643-5000 (9 

A

.

M

. to 5 

P

.

M

. EST) FAX: 203-643-5001 

Summary of Contents for COMHP 7404

Page 1: ...128 Byte FIFO Buffer with 4 DB 9M Cable or 4 DB 25M Cable D25 Model USER S MANUAL VER 2 0C Jun 10 No part of this manual may be reproduced without permission CyberResearch Inc Hwww cyberresearch com...

Page 2: ......

Page 3: ...ed for identification purposes only and may be trademarks and or registered trademarks of their respective companies NOTICE CyberResearch Inc does not authorize any CyberResearch product for use in li...

Page 4: ...COMHP 7404 D25 CyberResearch Serial Communications Revision History Revision Description Date of Issue 1 0 Initial Release May 1 2007 2 0C Revision June 9 2010 iv Copyright 2010 CyberResearch Inc...

Page 5: ...ERATING SYSTEM INSTALLATION 7 For Windows Users 7 Other Operating Systems 7 SYSTEM INSTALLATION 7 TECHNICAL DESCRIPTION 8 CONNECTOR PIN ASSIGNMENTS 8 RS 422 485 DB 9 Male 8 RS 232 DB 9 Male 8 CONNECTO...

Page 6: ...Echo and the termination resistor in circuit 3 Figure 3 Switches SW1 SW4 RS 485 Auto Enabled with Echo and no termination resistor in circuit 3 Figure 4 Switches SW1 SW4 RS 485 RTS Enabled with No Ec...

Page 7: ...485 mode our special auto enable feature allows the RS 485 ports to be viewed by the operating system as a COM port This allows the standard COM driver to be utilized for RS 485 communications Our on...

Page 8: ...AT The Auto enable feature automatically enables disables the RS 485 interface The RTS mode uses the RTS modem control signal to enable the RS 485 interface and provides backward compatibility with e...

Page 9: ...ON OFF AT RT NE T Figure 2 Switches SW1 SW4 RS 485 Auto Enabled with No Echo and the termination resistor in circuit 1 2 3 4 ON OFF AT RT NE T Figure 3 Switches SW1 SW4 RS 485 Auto Enabled with Echo...

Page 10: ...in circuit 1 2 3 4 ON OFF AT RT NE T Figure 5 Switches SW1 SW4 RS 485 RTS Enabled with Echo and no termination resistor in circuit Address and IRQ selection The COMHP 7404 is automatically assigned re...

Page 11: ...on to aid in the configuration of your electrical interface E5 E6 Port 2 RS 232 RS 422 E7 E8 Port 1 RS 232 RS 422 RS 422 485 E1 E2 Port 4 RS 232 RS 422 E3 E4 Port 3 RS 232 RS 422 RS 232 E5 E6 Port 2 R...

Page 12: ...reen D1 Baud Rates and Divisors for the DIV1 mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the DIV1 mode For this Data Rat...

Page 13: ...ppropriate section of the Serial Utilities Software System Installation The COMHP 7404 can be installed in any of the PCI expansion slots and contains configuration options for each port that must be...

Page 14: ...gative 3 Output RTS Request To Send Positive 6 Output RTS Request To Send Negative 7 Output RX Receive Data Positive 1 Input RX Receive Data Negative 2 Input CTS Clear To Send Positive 9 Input CTS Cle...

Page 15: ...m Connector Pin Assignments RS 232 RS 422 485 DB 37 Male Port 1 2 3 4 RS 422 485 RS 232 RX DCD 37 10 28 1 RX RD 36 11 27 2 TX TD 35 12 26 3 TX DTR 34 13 25 4 GND GND 33 14 24 5 RTS DSR 18 29 9 20 RTS...

Page 16: ...ring All Systems Printed Circuit boards are built to U L 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel Power...

Page 17: ...unique IRQ While the CyberResearch adapter does allow the sharing of IRQs many other adapters i e SCSI adapters on board serial ports do not The IRQ is typically selected via an on board header block...

Page 18: ...lanced interface meaning that a single electrical signal is compared to a common signal ground to determine binary logic states A voltage of 12 volts usually 3 to 10 volts represents a binary 0 space...

Page 19: ...as electrical characteristics that allow for 32 drivers and 32 receivers to be connected to one line This interface is ideal for multi drop or network environments RS 485 tri state driver not dual sta...

Page 20: ...op bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Remain Idle or next start bit Odd Even or Unused STOP P BIT 5 to 8 Data Bits Idle state of line...

Page 21: ...CyberResearch Serial Communications COML 4232U D25 Appendix D Silk Screen 4 2 6 5 CyberResearch Inc 15 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com...

Page 22: ...C Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission 16 Copyright 2...

Page 23: ...urements of the signals you are trying to measure as well as the signals on the board module or power supply 4 Isolate problem areas that are not working as you expected 5 Have the source code to the...

Page 24: ...COMHP 7404 D25 CyberResearch Serial Communications Intentionally Blank 18 Copyright 2010 CyberResearch Inc...

Page 25: ...urchased and in lieu of all other warranties expressed implied or statutory including but not limited to any implied warranty of merchant ability or fitness and all other obligations or liabilities of...

Page 26: ...COMHP 7404 D25 CyberResearch Serial Communications Intentionally Blank 20 Copyright 2010 CyberResearch Inc...

Page 27: ......

Page 28: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 643 5000 F 203 643 5001 www cyberresearch com...

Reviews: